MK16 Basics Flashcards

1
Q

Why don’t you mix Co2 absorbent?

A

Can cause channeling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does channeling of absorbent mean?

A

Gas can bypass granules and enter the breathing loop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How long is absorbent good for?

A

30 Days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the MK-16?

A

Electronically controlled
closed circuit
mixed gas
maintains constant partial pressure UBA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How is partial pressure of O2 primarily controlled?

A

Battery powered electronic module

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the 2 partial pressure modes and depths for descent and ascent?

A

.75 down to 33 FSW
1.3 past 33 FSW and up to 13 FSW on ascent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When is breathing gas vented

A
  • During ascent when gas volume increases
  • When diver manually adds and exceeds gas
  • When breathing loop pressure exceeds surround water pressure during normal operations
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the normal working limit for MK16 N2O2 and HEO2?

A

N2 - 150
HE - 300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is O2 duration apprx?

A

5 hours at consumption rate of 1.4lpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is absorbent duration directly impacted by and how?

A

Environment temp and depth
( Duration decreases with decreased temps and increased depths)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly