MK 16 EP's Flashcards

1
Q

Alternating Red/Green Other than Transition: 2 Sensors 1.15 to 1.45, 3 sensor +1.45 or -1.15

A

Sensor out of limits, ensure at least 2 sensors within 1.15-1.45 ata, continue dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Alternating Red/Green Other than Transition: All 3 sensors 1.15 to 1.45

A

Low primary battery, Use secondary display to monitor, terminate dive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Flashing Green (other than descent) : 2 more 02 sensors +1.45

A

High 02PP, Monitor secondary, close 02, manually add 02 to maintain 1.15-1.45 terminate dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Flashing red (other than descent) : 2 or more sensors - than 1.15

A

Low 02, Water intrusion in the scrubber, Monitor both displays, manually add to maintain between 1.15-1.45, using highest pp02, terminate dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Flashing red (other than descent) : Low 02 PP, Low 02 bottle pressure

A

Monitor secondary, add diluent to maintain .16, breath open circuit, terminate dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

No Primary display: Dropping secondary display readings

A

Primary Electronics Failure (PEA), Monitor Secondary, manually maintain 1.15-1.45, abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

No Primary display: Stable secondary display readings

A

Primary Display/Cable Failure. Monitor Secondary, maintain 1.15-1.45, with 02 or diluent, abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

No Primary display: Increasing secondary display readings

A

PEA Failure, Monitor secondary, close 02 bottle manually add to maintain 1.15-1.45, abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

No Gas addition: 02 valve is depressed

A

02 bypass failed/bottle closed - empty, Monitor secondary, add diluent to maintain .16 ata switch to open circuit, abort.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

No Gas addition: Diluent bypass failed, closed/empty

A

Monitor secondary, stay on closed circuit, abort

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Continuous gas venting:Hear or feel gas escaping from MK16 02 leak

A

02/diluent bypass/addition failed or stuck open. MSD Close both bottles check indicators. 02 continues to drop keep closed open diluent manually drive adding 02 as required to maintain 1.15-1.45 abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Continuous gas venting:Hear or feel gas escaping from MK16 diluent leak

A

Diluent indicator drops leave closed, open 02, use diluent as needed fro volume makeup as required, abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Inhalation difficulty

A

Insufficient gas in breathing loop, MSD, add diluent until diaphragm vents on exhalation. continue dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Increased breathing resistance: gurgling/decreased buoyancy

A

Leak in recirculation system/pneumatics, Head up attitude, add diluent to force water out through dump, breathe open circuit, abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Complete rig flood out: water filled breathing loop

A

Leak in recirculation system/pneumatics, Head up attitude, add diluent to force water out through dump, breathe open circuit, abort dive.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

No secondary display readings

A

SD blank fading, Monitor primary terminate dive

17
Q

C02 buildup: Hypercapnia

A

C02 absorbent failure, add diluent to vent rig, breathe open circuit, abort dive.

18
Q

Conflict between Primary and Secondary display: low or - secondary display with green primary.

A

Water intrusion into both scrubber and secondary cable, Monitor both displays, manually adding o2 using the highest ppo2, abort dive

19
Q

UBA fails to switch from .75 to 1.3:Flashing green on primary display, sensor reading above .90

A

Failed hydrostatic switch, Monitor both Primary/Secondary abort dive.