Minnesota Building Code Flashcards

1
Q

An institutional occupancy is typically considered Group _____.

A

I

Section 308.1 Institutional Group I pg 66

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A group ____ occupancy is the general classification for miscellaneous and utility structures.

A

U

Section 312.1 General pg 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Accessory religious educational rooms need not be considered separate occupancies where the occupant load is less than _______ occupants.

A

100

Section 305.1.1 Accessory to Places of Religious Worship pg 61

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

An accessory assembly area may be classified as a group B occupancy where the floor area is a maximum of _______ square feet.

A

749

Section 303.1.2 Small Assembly Spaces, #2 pg 60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In a group E middle school, an assembly area associated with the Group E shall be classified as what occupancy?

A

Group E

Section 303.1.3 Associated with Group E Occupancies pg 60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which of the following uses Is typically considered a Group A-4 occupancy?

A. Restaurant with a dance floor

B. School library

C. Outdoor football stadium

D. Indoor Hockey arena

A

D. Indoor hockey arena

Section 303.5 Assembly Group A-4 pg 61

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which of the following uses is not considered a Group B occupancy?

A. Convenience Store

B. Motor vehicle showroom

C. Car wash

D. Ambulatory care facility

A

A. Convenience store

Section 304.1 Business Group B pg 61

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The gaming floor of a large casino shall be classified as a Group _______ occupancy.

A

A-2

Section 303.3 Assembly Group A-2 pg 60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A group _______ occupancy classification is to be assigned to a facility where combustible dusts are generated in a manner that creates a fire or explosion hazard.

A

H-2

Section 307.4 High-hazard Group H-2 pg 65

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Buildings containing materials that present a detonation hazard are typically considered _______ occupancies.

A

H-1

Section 307.3 High-hazard Group H-1 pg 65

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A foster care facility providing care on a 24-hour basis to 6 or more infants/toddlers (2 1/2 years of age or less) is classified as a Group ______ occupancy.

A

I-2

Section 308.3 Institutional Group I-2 pg 66

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Prior to any permitted increases, the maximum allowable quantity per control area of a Class IB flammable liquid permitted in a storage condition in a one-story Group F-1 occupancy is _______ gallons.

A

120

Table 307.1(1) Maximum Allowable Quantity per Control Area of Hazardous Materials Posing a Physical Hazard pg 63

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which one of the following uses is not considered a Group M occupancy?

A. Wholesale store

B. Retail sales room

C. Motor vehicle showroom

D. Motor vehicle service station

A

C. Motor vehicle showroom

Section 309.1 Mercantile Group M pg 67 and 68

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A fraternity house with 40 occupants is considered a Group ______ occupancy.

A

R-2

Section 310.3 Residential Group R-2 pg 68

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which one of the following facilities with 12 residents living in a supervised environment and receiving custodial care would not be considered a Group R-4 occupancy?

A. Halfway house

B. Drug abuse center

C. Group home

D. Detoxification facility

A

D. Detoxification facility

Section 310.5 Residential Group R-4 pg 68

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which of the following uses is not considered a Group S-2 occupancy?

A. Open parking garage

B. Enclosed parking garage

C. Dry cell battery storage

D. Stable

A

D. Stable

Section 311.3 Low-Hazard Storage, Group S-2 pg 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

A food processing establishment not associated with a restaurant or similar dining facility is classified as a Group B occupancy where it is a maximum of ________ square feet.

A

2500

Section 304.1 Business Group B pg 61

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

A manufacturing facility utilizing highly toxic materials exceeding the maximum allowable quantities set forth in Table 307.1(2) is considered a ___________ occupancy.

A

Group H-4

Section 307.6 High-hazard Group H-4 pg 66

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Aerosol product storage buildings shall be classified as Group ______ occupancies when constructed in accordance with the International Fire Code.

A

S-1

Section 311.2 Moderate-Hazard Storage, Group S-1 pg 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Owner occupied lodging houses are permitted to be constructed in accordance with the International Residential Code where there are a maximum of _____ guest rooms or more than ______ occupants.

A

6
10

Section 310.2 Residential Group R-1 pg 68

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Where a training and skill development use not classified as a Group A occurs in other than a school or academic program, it is classified as a Group ____ occupancy.

A

B

Section 304.1 Business Group B pg 61

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

A congregate living facility (transient) with an occupant load of 8 persons is to be classified as a Group _______ occupancy.

A

R-3

Section 310.4 Residential Group R-3 pg 68

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

By definition, a transient residential dwelling unit or sleeping unit has a maximum occupancy period of _______ days.

A

30

Section Definitions, Transient pg 53

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Unless protected by an automatic sprinkler system, what is the minimum fire separation between a 350 square foot laundry room and the manufacturing building it is incidental to?

A

1-hour fire barrier and/or horizontal assembly

Table 509 Incidental Uses and Section 509.4.1 Separation pg 132 and 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

What minimum level of incidental use protection is required for an incinerator room located in a manufacturing facility?

A

Separation of 2 hours and an automatic sprinkler system

Table 509 Incidental Uses, Incinerator Rooms pg 132

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

What minimum level of incidental use protection is required for a chemistry laboratory/classroom in a high school?

A

Either a 1-hour fire barrier/horizontal assembly or an automatic sprinkler system

Table 509 Incidental Uses, In Group E Occupancies, Laboratories and Vocational Shops Not Classified as Group H

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Where an automatic sprinkler system without a fire barrier is utilized for the protection of incidental use areas, what minimum level of separation is required?

A

Construction capable of resisting the passage of smoke

Section 509.4.2 Protection pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Aggregate accessory occupancies are limited to a maximum floor area of _____ percent of the area of the story in which they are located.

A

10

Section 508.2.3 Allowable Building Area pg 130

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Any accessory occupancy area classified as a Group ________ occupancy must always be separated by a fire barrier and/or horizontal assembly from other occupancies in the building.

A

H-3

Section 508.2.4 Separation of Occupancies Exception #1 pg 130

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Where provisions for nonseparated occupancies are used for a mixed-occupancy building, the most restrictive _______________ requirements shall apply to the nonseparated uses.

A

Chapter 9 (fire protection)

Section 508.3.1 Occupancy Classification pg 130

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Where the provisions for separated occupancies are used for a nonsprinklered mixed occupancy building, the minimum separation between a Group A-2 and a Group B occupancy shall be a what?

A

2-hour fire barrier/horizontal assembly

Table 508.4 Required Separation of Occupancies pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

Where the provisions for separated occupancies are used for a sprinklered mixed occupancy building, the minimum separation between a Group H-2 and Group F-1 occupancy shall be what?

A

2-hour fire barrier/horizontal assembly pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Where the provisions for separated occupancies are utilized for a fully sprinklered building housing both a Group A-2 occupancy and a Group R-1 occupancy, the minimum required separation between the two occupancies shall be what?

A

1-hour fire barrier/horizontal assembly

Table 508.4 Required Separation of Occupancies pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

Under the provisions for separated occupancies, what is the minimum hourly fire resistance rated separation required between a Group F-1 occupancy and a Group S-1 occupancy where located in a non-sprinklered building?

A

0 hours (no separation requirement)

Table 508.4 Required Separation of Occupancies pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

Buildings used for the storage of beverages having an alcohol content over 16 percent are to be classified as Group _______ occupancies.

A

S-1

Section 311.2 Moderate Hazard Storage Group S-1 and Section 311.3 Low Hazard Storage Group S-2 pg 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Fences are to be classified as Group U occupancy where more than ____ feet in height.

A

6

Section 312.1 General pg 69

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Where mass timber elements serve as fire barriers used as incidental use separations in Type IV-B buildings, gypsum board used as a thermal barrier on the side of the incidental use shall be a minimum ___________.

A

1/2 inch

Section 602.4.2 Cross-laminated Timber in Exterior Walls #2 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

I’m the determination of allowable building area for a mixed occupancy building, the __________ occupancies method requires the sun of the ratios of the actual building area of each occupancy divided by the allowable building area of each occupancy to be not greater than 1.0.

A

Separated

Section 508.4.2 Allowable Building Area pg 130

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

What types of construction in the Minnesota building code are considered “noncombustible”?

A

Types I, II, III, IV

Section 602.2 Types I and II, 602.3 Type III, 602.4 Type IV, 602.5 Type V pg 135 and 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

Type III buildings are constructed with ___________ or fire-retardant treated wood exterior walls and interior elements _________________.

A

Noncombustible
Of any materials permitted by this code

Section 602.3 Type III pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

The type of construction where building elements are mass timber or noncombustible is?

A

Type IV

Section 602.4 Type IV pg 135 and 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

In buildings of Type III construction, under what condition is fire-retardant treated wood framing permitted within an exterior wall assembly?

A

The wall has a 2-hour rating or less

Section 602.3 Type III pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

Where supporting floor loads, solid sawn wood columns of type IV-HT construction shall be of what minimum nominal size?

A

8” by 8”

Section 602.4 Type IV then to Table 2304.11 Minimum Dimensions of Heavy Timber pg 136 and 522

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

Where used in floor framing, solid sawn wood beams of Type-IV-HT construction shall be of what minimum nominal size?

A

6” by 10”

Section 602.4 Type IV then to Table 2304.11 Minimum Dimensions of Heavy Timber pg 136 and 522

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

Which of the following materials is permitted in a building of Type VB construction?

A. Wood

B. Steel

C. Masonry

D. All of the above

A

D. All of the above

Section 602.5 Type V pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
46
Q

In a building of Type IB construction, what is the minimum required fire-resistance rating of the floor construction?

A

2 hours

Table 601 Fire Resistance Rating Requirements for Building Elements pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
47
Q

Which of the following members is not considered to be part of the primary structural frame in the Minnesota Building Code?

A. Columns supporting only a roof load

B. Girders supporting no more than a floor and a roof

C. Members essential to the vertical stability of the frame under gravity loads

D. Floor joists not having direct connections to columns

A

D. Floor Joists not having direct connections to columns

Table 601 Fire Resistance Rating Required for Building Elements then to Section 202 Definitions: Primary Structural Frame pg 135 and 47

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
48
Q

In a building of Type IIB construction, what is the minimum required fire-resistance rating of the roof construction?

A

0 hours (no rating required)

Table 601 Fire Resistance Rating Requirements for Building Elements pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
49
Q

In a building of Type VA construction, which of the following building elements does not require a minimum of 1-hour fire resistance rating?

A

Interior nonbearing wall

Table 601 Fire Resistance Rating Requirements for Building Elements pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
50
Q

In a one-story Type-IA building, what is the minimum required Fire resistance rating for the interior bearing walls supporting the roof only?

A

2 hours

Table 601 Fire Resistance Rating Requirements for Building Elements, Exception a pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
51
Q

In Type IA buildings limited to two stories in height, what building element is permitted to be constructed of fire-retardant treated wood?

A

Roof construction

Section 603.1 Allowable Materials #1.3 See Exception pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
52
Q

In a Type IB building housing a Group A-4 occupancy, fire protection of the roof structural members, framing and decking is not required where every portion of the roof construction is a minimum of _____ feet above the door below.

A

20

Table 601 Fire Resistance Rating Requirements for Building Elements, Exception B pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
53
Q

Complying heavy timber columns and arches are permitted to be used externally where a minimum ______ foot horizontal separation is provided.

A

20

Section 602.4.3 Exterior Structural Members pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
54
Q

I’m a Type VB building housing a Group B occupancy, what is the minimum required rating for an exterior bearing wall located with a fire separation distance of 10 feet?

A

0 hours (no rating required)

Table 601 Fire Resistance Rating Requirements for Building Elements, Exceptions e and f, Table 602 Fire Resistance Rating Requirements for Exterior Walls Base on Fire Separation Distance pg 135 and 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
55
Q

What is the minimum required Fire Resistance rating for roof construction in a building of Type IA construction?

A

1 1/2 hours

Table 601 Fire Resistance Rating Requirements for Building Elements pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
56
Q

In a building of Type I or II construction, nonbearing partitions having a maximum fire resistance rating of _________ are permitted to be constructed of fire retardant treated wood.

A

2 hours

Section 603.1 Allowable Materials #1.1 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
57
Q

When used in Type IV-HY floor construction, cross laminated timber shall be a minimum of _____ inches in actual thickness.

A

4

Section 602.4 Type IV to Section 2304.11.3.1 Cross Laminated Timber Floors pg 136 and 521

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
58
Q

In a building of Type I or II construction, nonbearing exterior walls having a maximum fire resistance rating of ______ are permitted to be constructed of fire retardant treated wood.

A

0 hours (no rating required)

Section 603.1 Allowable Materials #1.2 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
59
Q

Show windows may be of combustible construction in a Type I and II construction where located a maximum of ________ above grade.

A

15 ft

Section 603.1 Allowable Materials, Exception 9 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
60
Q

Which type of roof covering is not permitted on an office building of Type IIB construction?

A. Class A

B. Class B

C. Class C

D. Nonclassified

A

D. Nonclassified

Section 603.1 Allowable Materials Exception 4 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
61
Q

Which of the following methods of construction is not permitted for interior partitions in Type IV-HT structures?

A. Two layers of 1/2 inch fire retardant treated structural wood panels

B. 4 inches of laminated solid wood construction

C. Two layers of 1 inch matched boards

D. One hour fire resistance rates construction

A

A. Two layers of 1/2 inch fire retardant treated structural wood panels

Section 602.4 Type IV to Section 2304.11.2.2 Interior Walls and Partitions pg 136 and 521

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
62
Q

What is the minimum required vertical distance between the upper floor and the roof to allow the use of fire retardant treated wood in the roof construction of an eight story type IA building?

A

20 feet

Section 603.1 Allowable Materials #1.3 See Exception pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
63
Q

In a building of Type IIA construction, heavy timber members may be used in lieu of one hour fire resistance rated construction for which building element?

A

Roof construction

Table 601 Fire Resistance Rating Requirements for Building Elements, Exception C pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
64
Q

For an office building of Type IB construction, what is the minimum required fire resistance rating for an exterior bearing wall located on an interior lot line?

A

2 hours

Table 601 Fire Resistance Rating Requirements for Building Elements pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
65
Q

In a building of Type IV-HT construction, 1 hour combustible construction is permitted in lieu of heavy timber construction for which of the following building elements?

A

Interior bearing walls

Table 601 Fire Resistance Rating Requirements for Building Elements then to Section 2304.11.2.2 Interior Bearing Walls and Partitions pg 135 and 521

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
66
Q

What is the minimum required fire resistance rating for the floor construction in a Type IIIB building?

A

0 hours (no rating required)

Table 601 Fire Resistance Rating Requirements for Building Elements pg 135

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
67
Q

A glued-laminated beam, where utilized in a Type IV-HT building requiring a 6” by 10” solid sawn member of nominal size, shall have a minimum net finished size of what?

A

5” by 10 1/2”

Section 602.4 Type IV to Table 2304.11 Minimum Dimensions of Heavy Timber Structural Members pg 135 and 522

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
68
Q

Under general conditions, thermal and acoustical insulation other than foam plastic is permitted to be installed in buildings of Type I or II construction, provided the insulation has a maximum flame spread index of what?

A

25

Section 603.1 Allowable Materials #2 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
69
Q

In buildings of Type I and II construction, fire retardant treated wood may be used in the construction of balconies not used for egress purposes where the building is a maximum of _____ stories above grade plane.

A

3

Section 603.1 Allowable Materials #1.4 pg 136

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
70
Q

In a fully sprinklered Type IIB building, freezer wall construction may be of combustible materials where the freezer is a maximum of _______ square feet in size and the walls are lined with noncombustible materials on both sides.

A

999

Section 603.1 Allowable Materials, Exception #26 pg 137

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
71
Q

Commercial buildings must be identified by numbers or addresses visible from the street, with a minimum character height of at least ______ inches.

A

4

Section 502.1 Address Identification pg 119

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
72
Q

Building height is measured to the what?

A

Average height of the highest roof surface

Section 202 Definitions, See Height, Building pg 40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
73
Q

The tabular allowable Building height for a fully-sprinklered single occupancy Type IB building housing a Group I-2 occupancy is _____ stories and _________ feet.

A

5
180

Table 504.3 Allowable Building Height in Feet Above Grade Plane and Table 504.4 Allowable Number of Stories Above Grade Plane pg 120 and 122

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
74
Q

What is the tabular allowable height, in feet, for a single occupancy nonsprinklered Group B building of Type IIA construction?

A

65

Table 504.3 Allowable Building Height in Feet Above Grade Plane pg 120

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
75
Q

Basements do not need to be included in the total allowable area of a single occupancy building, provided the total area of such basements do not exceed what?

A

The area permitted for a one story above grade plane building

Section 506.1.3 Basements pg 124

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
76
Q

The maximum building area of a six story single occupancy building is limited to ____ times the allowable area permitted per story.

A

Three

Section 506.2.3 Single Occupancy, Multi-story Buildings, Equation 5-2 S^a pg 124

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
77
Q

What is the maximum allowable height in feet above grade plane for a fully sprinklered single occupancy type IIA building housing a Group A-2 occupancy?

A

85 feet

Table 504.3 Allowable Building Height in Feet Above Grade Plane pg 120

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
78
Q

What is the maximum allowable number of stories above grade plane for a fully sprinklered single occupancy IIIB building housing a Group I-2 occupancy?

A

0 it is not permitted

Table 504.4 Allowable Number of Stories Above Grade Plane pg 122

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
79
Q

Combustible steeples are limited to a maximum height of ______ feet above the allowable building height.

A

20

Section 504.3 Height in Feet, See Exception pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
80
Q

The area of a mezzanine is not to be included in the determination of the what?

A

Building area

Section 505.2 Mezzanines pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
81
Q

A minimum clear height of __________ is required above and below mezzanine floor construction.

A

7 feet

Section 505.2 Mezzanines pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
82
Q

In general, the aggregate area of mezzanines within a room is limited to __________ of the area of the room in which the mezzanines are located.

A

33 1/3 percent

Section 505.2.1 Area Limitation pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
83
Q

Portions of a mezzanine need not be open to the room in which the mezzanine is located, provided the enclosed space is limited in size to a maximum of __________ of the mezzanine area.

A

10%

Section 505.2.3 Openness, Exception #3 pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
84
Q

A mezzanine is not required to be open to the room in which it is located where the occupant load of the enclosed space does not exceed what?

A

10

Section 505.2.3 Openness, Exception #1 pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
85
Q

An allowable area increase for frontage is not permitted unless a minimum of __________ of the building perimeter is sufficiently open.

A

25 percent

Section 506.3.1 Minimum Percentage of Perimeter pg 127

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
86
Q

In order to be considered as sufficiently open for an allowable area increase for frontage, the public way or open space must have a minimum width of _____ feet.

A

20

Section 506.3.2 Minimum Frontage Distance pg 127

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
87
Q

What is the allowable tabular height, in number of stories above grade plane, for a Group R-1 single occupancy building of Type IIB construction where the building is protected by an NFPA 13R sprinkler system?

A

4

Table 504.4 Allowable Number of Stories Above Grade Plane, See Exception, then to Section 903.3.1.2 NFPA 13R Sprinkler System pg 123 and 238

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
88
Q

What is the allowable building area factor for a nonsprinklered Type VB building housing a Group B occupancy?

A

9000 square feet

Table 506.2 Allowable Area Factor in Square Feet pg 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
89
Q

The maximum permitted aggregate area of mezzanines, per story, in a Type IIB building provided with a sprinkler system and an emergency voice/alarm communication system is _____________ of the floor area.

A

50 percent

Section 505.2.1 Area Limitation, Exception #2, pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
90
Q

What is the maximum allowable number of stories above grade plane permitted for a single-occupancy Type IIIA building housing a Group R-2 occupancy that is provided with a 13R sprinkler system?

A

4

Table 504.4 Allowable Number of Stories Above Grade Plane pg 123

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
91
Q

In order for a Group E building to comply with the unlimited area allowances of Section 507, the buildings construction type cannot be Type _______.

A

IIIB

Section 507.11 Group E Buildings pg 129

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
92
Q

In order to reduce the required open space surrounding certain unlimited area buildings from 60 ft to 40 ft, walls facing the reduced open space shall have a minimum fire-resistance rating of ____________.

A

3 hours

Section 507.2.1 Reduced Open Space #2 pg 128

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
93
Q

A complying Group H-2 aircraft paint hangar may be unlimited in floor area when limited to one story, provided the hangar is surrounded by yards or public ways having a minimum width of what?

A

One and a half times the height of the hangar

Section 507.10 Aircraft Paint Hangar pg 129

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
94
Q

Where using the special provisions of Section 510.2 for the horizontal building separation allowance, the horizontal separation between buildings shall be provided with a horizontal assembly having a minimum __________ fire resistance rating.

A

3-hour

Section 510.2 Horizontal Building Separation Allowance #1 pg 132

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
95
Q

What is the maximum allowable height permitted for a noncombustible communications tower located on the roof of a Type IIB office building?

A

Unlimited

Section 504.3 Height in Feet, See Exception pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
96
Q

In order for a Type IIIB office building to be considered for unlimited area under Section 507, it must be limited to a maximum height of ____________ above grade plane.

A

One story

Section 507.7 Group A-3 Buildings of Type III and IV Construction pg 128

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
97
Q

A one story Group A-3 gymnasium building of Type IIIA construction may be considered under the unlimited area provisions, provided the gymnasium floor is located a maximum of _________ above or below grade level.

A

21 inches

Section 507.7 Group A-3 Buildings of Type III and IV Construction pg 128

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
98
Q

A group H-3 storage room located within a 100,000 square foot unlimited area manufacturing building of Type IIB construction is limited to ________ square feet where not located on the buildings perimeter.

A

3500

Section 507.8.1.1 Located Within the Building then to Table 506.2 Allowable Area Factor in Square Feet pg 129 and 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
99
Q

A nine-story apartment building of Type IIA construction, where permitted, shall be located a minimum of _____ feet from any other building on the lot and from all lot lines.

A

50

Section 510.6 Group R-1 and R-2 Buildings of Type IIA Construction pg 133

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
100
Q

In buildings of Type I or II construction housing special industrial occupancies in accordance with section 503.1.1, the aggregate floor area of mezzanines is limited to a maximum of ________ of the area of the room in which they are located.

A

2/3

Section 505.2.1 Area Limitation, Exception #1 pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
101
Q

Where the aggregate area of all equipment platforms within a room is limited to a maximum of ______ of the area of the room in which they are located, the equipment platforms shall not be considered a portion of the floor below.

A

2/3

Section 505.3.1 Area Limitation pg 123

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
102
Q

The area of a complying covered mall building and any anchor stores is not limited where their maximum height is ______ stories.

A

3

Section 507.13 Covered and Open Mall Buildings and Anchor Buildings pg 129

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
103
Q

A group E building of unlimited area under the conditions of section 507 shall be surrounded and adjoined by public ways and it’s a minimum of _____ feet in width.

A

60

Section 507.11 Group E Buildings, #3 pg 129

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
104
Q

What is the maximum allowable building height in feet above grade plane for a single occupancy nonsprinklered IIIB building housing a Group B occupancy?

A

55

Table 504.3 Allowable Building Height in Feet Above Grade Plane pg 120

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
105
Q

Regardless of other conditions, mezzanines used for control equipment are permitted to be glazed on all sides in ___________ facilities.

A

Industrial

Section 505.2.3 Openness, Exception #4 pg 121

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
106
Q

An opening around a penetrating item is an ________________.

A

Annular Space

Section 202 Definitions, Annular Space pg 26

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
107
Q

A what, is a listed device installed in a ceiling membrane of a fire resistance floor/ceiling or roof/ceiling assembly to limit automatically the radiative heat transfer through an air inlet/outlet opening?

A

Ceiling Radiation Damper

Section 717.3.3.4 Ceiling Radiation Damper Actuation pg 167

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
108
Q

The time period that a through penetration firestop system or perimeter fire containment system limits the spread of fire through a penetration or void is considered what?

A

An F Rating

Section 202 Definitions, F-Rating pg 36

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
109
Q

What consist of building materials installed to resist the free passage of flame to other areas of the building through concealed spaces?

A

Fireblocking

Section 202 Definitions, Fireblocking pg 37

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
110
Q

The measurement between the face of an exterior wall and the closest interior lot line is described as the what?

A

Fire separation distance

Section 202 Definitions, Fire Separation Distance pg 37

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
111
Q

A what, must have sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall?

A

Fire wall

Section 202 Definitions, Fire Wall pg 37

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
112
Q

A smoke compartment is a space within a building separated from other interior areas of the building by ___________, including interior walls and horizontal assemblies.

A

Smoke barriers

Section 202 Definitions, Smoke Compartment pg 49

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
113
Q

The T rating for a penetration firestop system is based on a maximum temperature rise of _______ degrees F above its initial temperature through the penetration on the bonfire side when tested in accordance with ASTM E184 or UL 1479.

A

325

Section 202 Definitions, T rating pg 53

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
114
Q

Where a fire-resistance rating of building elements, components or assemblies is determined by test procedures, the procedures set forth in ASTM E119 or ___________ shall be applicable.

A

UL 263

Section 703.2 Fire-Resistance Ratings pg 139

115
Q

Where a fire barrier is required to be identified by signage in an accessible concealed attic space, the identification shall occur at maximum intervals of ______ feet measured horizontally along the wall.

A

30

Section 703.7 Marking and Identification #1 pg 140

116
Q

Composite materials with a noncombustible structural base are considered noncombustible where the surface material is limited to _______ inch in thickness and has a maximum flame spread index of _____.

A

1/8”
50

Section 703.5.2 Composite Materials pg 140

117
Q

A projection extending beyond an exterior wall located 6 feet from an interior lot line shall be located such that a minimum of ________ inches is provided between the lot line and the edge of the projection.

A

40

Table 705.2 Minimum Distance of Projection pg 142

118
Q

Projections beyond an exterior wall are permitted where the exterior wall has a minimum fire separation distance of _______ inches.

A

24

Table 705.2 Minimum Distance of Projection pg 142

119
Q

In a building of Type III construction, projections may be what?

A

Of any approved materials

Section 705.2.2 Type III, IV, or V Construction pg 142

120
Q

For wall and opening protection, projections and roof covering requirements, an assumed imaginary line shall be placed between ________________ unless they are considered a single building.

A

Buildings on the same lot

Section 705.3 Buildings on the Same Lot pg 142

121
Q

The fire-resistance rating for an exterior wall shall be based on both interior and exterior fire exposure where the wall is located a maximum of _____ feet from and interior lot line.

A

10

Section 705.5 Fire-Resistance Ratings pg 143

122
Q

In a nonsprinklered Type VB building, what is the maximum permissible area of unprotected exterior wall openings for a fire separation distance of 8 feet?

A

10 percent

Table 705.8 Maximum Area of Exterior Wall Openings Based on Fire Separation Distance and Degree of Opening Protection pg 145

123
Q

In a nonsprinklered Type IIIA building, what is the maximum allowable area of protected exterior wall openings for a fire separation distance of 20 feet?

A

Unlimited

Table 705.8 Maximum Area of Exterior Wall Openings Based on Fire Separation Distance and Degree of Opening Protection pg 145

124
Q

In a fully sprinklered type IIB office building, what is the maximum allowable area of unprotected exterior wall openings for a fire separation distance of 5 feet?

A

25 percent

Table 705.8 Maximum Area of Exterior Wall Openings Based on Fire Separation Distance and Degree of Opening Protection pg 145

125
Q

In other than group H occupancies, unlimited unprotected exterior openings are permitted in the first story above grade of exterior walls facing an unoccupied space of at least ______ feet in width.

A

30

Section 705.8.1 Allowable Area of Openings Exception #1.2 pg 143

126
Q

Where flame barriers are required for the vertical separation of exterior openings in adjacent stories, horizontal barriers must extend at least ______ inches beyond the exterior wall.

A

30

Section 705.8.5 Vertical Separation of Openings pg 143 and 144

127
Q

Flame barriers protecting openings in exterior walls in adjacent stories shall have a minimum fire-resistance rating of what?

A

1 hour

Section 705.8.5 Vertical Separation of Openings pg 143 and 144

128
Q

A parapet is not required at an exterior wall of a building having a maximum floor area of _________ square feet on each floor.

A

1000

Section 705.11 Parapets, Exception #2

129
Q

Where required at exterior walls, parapets must extend a minimum of ______ inches above the point where the roof surface and wall intersect.

A

30

Section 705.11.1 Parapet Construction pg 146

130
Q

The uppermost portion of parapet walls must have noncombustible faces for a minimum of _____ inches.

A

18

Section 705.11.1 Parapet Construction pg 146

131
Q

A roof eave extending to within 5 feet of the line used to determine fire separation distance may be constructed of all of the following materials except what?

A. Heavy-timber construction

B. Noncombustible materials

C. Fire retardant treated wood

D. 1/2 hour fire resistance rated combustible construction

A

D. 1/2 hour fire resistance rated combustible construction

Section 705.2.3 Combustible Projections pg 142

132
Q

In a fully sprinklered Type IIA building, the maximum allowable area of protected exterior wall opening is _____________ where the fire separation distance is 12 feet.

A

45 percent

Table 705.8 Maximum Area of Exterior Wall Openings Based on Fire Separation Distance and Degree of Opening Protection pg 145

133
Q

A parapet is not required on the exterior wall of a nonsprinklered building located a minimum of ______ feet from an interior lot line.

A

15

Section 705.11 Parapets, Exception #6 to Table 705.8 Maximum Area of Exterior Wall Openings Based on Fire Separation Distance and Degree of Opening Protection pg 146 and 145

134
Q

Unprotected openings are not permitted in the exterior wall of a Group H-3 warehouse where the fire separation distance is less than ______ feet.

A

15

Table 705.8 Maximum Area of Exterior Wall Openings Based on Fire Separation Distance of Opening Protection, Exception e pg 145

135
Q

The area of openings in an exterior wall of an open parking garage is permitted to be unlimited where there is a minimum fire separation distance of what?

A

10 feet

Table 705.8 Maximum area of Exterior Wall Openings Based on Fire Separation Distance and Degree of Opening Protection, Exception g pg 145

136
Q

A parapet is not required on an exterior wall where the wall terminates at a roof with a minimum fire resistance rating of what?

A

2 hours

Section 705.11 Parapets, Exception #3 pg 146

137
Q

A projection beyond a buildings exterior wall that is located 4 feet from an interior lot line shall be located such that a minimum of _______ inches is provided between the lot line and the edge of the projection.

A

32

Table 705.2 Minimum Distance of Projection pg 142

138
Q

In other than Group H occupancies, unlimited unprotected openings are permitted in a first story exterior wall that faces a street, provided the minimum fire separation distance is greater than what?

A

15 feet

Section 705.8.1 Allowable Area of Openings Exception 1.1 pg 143

139
Q

In a type IIB building housing a Group I-2 occupancy, what is the minimum required rating for an exterior nonbearing wall located with a fire separation distance of 8 feet?

A

1 hour

Section 705.5 Fire Resistance Rating then to Table 602 Fire Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance pg 143 and 136

140
Q

In a Type IIA building housing a Group R-2 occupancy, what is the minimum required rating for an exterior nonbearing wall located with a fire separation distance of 3 feet?

A

1 hour

Table 602 Fire Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance pg 136

141
Q

When an exterior bearing wall of a Group M occupancy of Type IIB construction is located 3 feet from an interior lot line, the wall must have a minimum fire resistance rating of _____ hours.

A

2

Section 705.5 Fire Resistance Rating to Table 601 Fire Resistance Rating Requirements for Building Elements then to Table 602 Fire Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance pg’s 143, 136 and 137

142
Q

A nonbearing exterior wall of a Type IB open parking garage complying with Section 406 shall have a minimum fire resistance rating of ____ hours where the fire separation distance is 10 feet.

A

0 hours (no rating required)

Section 406.5.6 Fire Separation Distance to Table 602 Fire Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance, Exception C pg 83 and 136

143
Q

Fire protection is not required at the bottom flange of a lintel that is part of the primary structural frame provided the maximum lintel span is what?

A

6 foot 4 inches

Section 704.11 Bottom Flange Protection pg 141

144
Q

Fire walls must be constructed of noncombustible materials unless separating buildings of Type ______ construction.

A

Type V

Section 706.3 Materials pg 146

145
Q

A fire wall separating Type VA buildings housing Group M occupancies must have a minimum fire resistance rating of what?

A

3 hours

BC Table 706.4 Fire Wall Fire Resistance Ratings pg 147

146
Q

In a Type IIB building containing a Group B occupancy, what is the minimum required fire-resistance rating for a fire wall?

A

2 hour

BC Table 706.4 Exception a pg 147

147
Q

As a general provision, what minimum distance must a fire wall in a building extend horizontally beyond the exterior surface of exterior walls?

A

18 inches

BC 706.5 pg 147

148
Q

In general, what minimum distance above the roof in a building must a fire wall extend?

A

30 inches

BC 706.6 pg 147

149
Q

Where a fire wall occurs at a location where the roof levels differ, the fire wall may terminate at the underside of the lower roof slab, provided three conditions are met including?
A. the lower roof is of noncombustible construction
B. the lower roof assembly within 10 feet of the fire wall has a minimum 1-hour rating
C. the exterior wall of the higher portion is 1-hour to a height of 10 feet.
D. openings in the lower roof have a minimum 45-minute fire-protective rating.

A

b. the lower roof assembly within 10 feet of the fire wall has a minimum 1-hour rating

BC 706.6.1 Exception #1 pg 148

150
Q

Embedded ends of combustible members entering masonry or concrete fire walls shall be separated a minimum distance of what?

A

4 inches

BC 706.7 pg 148

151
Q

Fire barriers are required for the separation of all of the following building elements except what?
A. shaft enclosures
B. exit passageways
C. incidental uses
D. fire-resistance-rated corridors

A

D. fore-resistance-rated corridors

BC 707.3.1-10 pg 149

152
Q

In Type VB buildings, construction supporting fire barriers need not be protected by equivalent fire resistance where the fire barriers are used for what?

A

1-hour incidental use separations

BC 707.5.1 Exception #2 pg 149

153
Q

In a nonsprinklered building, any single opening in a fire barrier used for separating control areas is limited to a maximum area of _______ square feet.

A

156 square feet

BC 707.6 Exception #1 pg 149 and 150

154
Q

Openings for the fire door assemblies in a fire barrier are permitted to be unlimited in area and aggregate width where the fire barrier is utilized as a what?

A

interior exit stairway enclosure

BC 707.6 Exception 2 and 5 pg 150

155
Q

Where vertical openings are created for an escalator system in a fully sprinklered hotel, special opening protection methods are established, other than automatic shutters, where the openings connect a maximum of ______ stories.

A

four stories

BC 712.1.3.1 pg 153

156
Q

Fire walls shall be designed and constructed for structural stability in accordance with IBC Section 706 or?

A

NFPA 221

BC 706.2 pg 146

157
Q

A fire barrier used as a horizontal exit shall have a minimum fire-resistance rating of what?

A

2 hours

BC 707.3.5 to 1026.2 pg 149 and 314

158
Q

A fire partition is not the appropriate wall assembly for walls separating what?
A. sleeping units in a Group R-1 hotel
B. tenant spaces in a covered mall building
C. control areas in a manufacturing occupancy
D. dwelling units in an apartment building

A

C. control areas in a manufacturing occupancy

BC 708.1 #1 through 5 pg 150

159
Q

What is the minimum required fire-resistance rating for a fire partition separating sleeping units in a Group I-1 occupancy housed in a Type IIA building?

A

1 hour

BC 708.3 Exception #2 pg 150

160
Q

Where a fire-resistance-rated corridor ceiling is constructed as required for the corridor walls, the walls shall not terminate before reaching what?

A

the upper membrane of the ceiling assembly

BC 708.4 Exception #3 pg 150

161
Q

In other than a Group I-3 occupancy, what is the minimum required fire-resistance rating for a smoke barrier?

A

1 hour

BC 709.3 pg 151

162
Q

In which of the following types of construction must a smoke barrier be supported by fire-resistance rated construction having at least an equivalent rating to the smoke barrier supported?
A. Type IIB
B. Type IIIA
C. Type IIIB
D. Type VB

A

B. Type IIIA

BC 709.4 pg 151

163
Q

Automatic shutters utilized to protect escalator openings between stories shall have a minimum fire-resistance rating of what?

A

1 1/2 hours

BC 712.1.3.2 pg 153

164
Q

Wire or other approved devices shall be installed above lay-in ceiling panels in a fire-resistance-rated floor/ceiling assembly to prevent vertical displacement where the weight of the panels is not adequate to resist a minimum upward force of what?

A

1 psf

BC 711.2.5 pg 153

165
Q

Under which of the following conditions may the ceiling membrane of a fire-resistance-rated horizontal assembly be omitted?

A

where an unusable crawl space occurs below

BC 711.2.6 pg 153

166
Q

Unprotected skylights are permitted through a fire-resistance-rated roof deck, provided that what?

A

the structural integrity of the roof construction is maintained

BC 712.1.15 pg 154

167
Q

Where a fire barrier is utilized to separate a Group M occupancy into multiple fire areas, the minimum fire-resistance rating of the fire barrier shall be what?

A

2 hours

BC Table 707.3.10 pg 149

168
Q

The voids created at the intersection of a fire barrier and a nonfire-resistance-rated roof assembly shall?

A

be filled by an approved material or system

BC 707.9 pg 150

169
Q

What hourly rating is mandated for the construction of smoke partitions?

A

0, no rating required

BC 710.3 pg 152

170
Q

Windows in smoke partitions shall have a minimum fire-protection rating of what?

A

0, no rating required

BC 710.5.1 pg 152

171
Q

In a Type IIB hotel that is sprinklered in accordance with NFPA 13, what is the minimum fire-resistance rating for the fire partitions and horizontal assemblies that separate sleeping units?

A

1/2 hour

BC 708.3 Exception #2 pg 150

172
Q

In general, fire walls shall extend to the outer edge of horizontal projecting elements that are located within _____ feet of the fire wall.

A

4 feet

BC 706.5.2 pg 147

173
Q

In which of the following uses must cross-corridor doors be provided with a vision panel?

A

ambulatory care facilities

BC 709.5.1 pg 152

174
Q

A shaft enclosure shall have a minimum 2-hour fire-resistance rating where connecting a minimum of _____ stories.

A

4 stories

BC 713.4 pg 155

175
Q

Where the annular space at the penetration of horizontal assemblies is filled with an approved material, noncombustible piping may connect a maximum of _____ stories, provided the horizontal assemblies require no fire-resistance rating.

A

5 stories

BC 714.6.1 pg 159

176
Q

In which of the following locations is a fire-resistant joint system required to protect all joints?
A. floors within malls
B. horizontal exit walls
C. mezzanine floors
D. roofs where openings are permitted

A

B. horizontal exit walls

BC 715.1 Exceptions 1-10 pg 159

177
Q

In a nonsprinklered building, a fire door assembly in an exit passageway shall have a maximum transmitted temperature end point of _______ degrees F above ambient at the end of 30 minutes of standard fire test exposure.

A

450 degrees F

BC 716.2.2.3 pg 161

178
Q

A fire door assembly in a 1-hour fire barrier used in an interior exit stairway enclosure shall have a minimum fire protection rating of what?

A

1 hour

BC Table 716.1(2) pg 162

179
Q

Fire door assemblies required in a 2-hour exterior wall shall have a minimum fire protection rating of what?

A

90 minutes (1 1/2 hours)

BC Table 716.1(2) pg 163

180
Q

Penetrations in what shall be tested for air leakage in accordance with the requirements of UL 1479?

A

smoke barriers

BC 714.5.4 pg 158

181
Q

Where an elevator lobby is used to provide hoistway protection required in a non-sprinklered building, it shall be separated from the floor level through the use of what?

A

fire partitions

BC 713.14 and 3006.3 #1 pg 156 and 618

182
Q

In which one of the following locations may self-closing or automatic-closing devices be omitted from required fire doors?

A

doors in common walls separating Group R-1 sleeping units

BC 716.2.6.1 Exception #1 pg 164

183
Q

Which one of the following fire-rated glazing markings is required for a sidelight adjacent to a 1-hour interior exit stairway door assembly?

A

W-60

BC Table 716.1(2) pg 162

184
Q

Where automatic-closing fire doors are installed, which one of the following locations does not require closing upon activation of smoke detectors?
A. cross-corridor doors in an office building
B. doors in a fire barrier separating control areas
C. a pair of doors installed in a fire wall
D. a single door installed in a smoke partition

A

A. cross-corridor doors in an office building

BC 716.2.6.6 #1-8 pg 164

185
Q

Access openings for waste or linen chutes shall be located in rooms enclosed by minimum _________ fire barriers.

A

1 hour

BC 713.13.3 pg 156

186
Q

Where a fire protection system is required to be monitored, the approved supervising station must comply with what?

A

NFPA 72

BC 901.6 pg 233

187
Q

In a Group A-2 occupancy, an automatic sprinkler system shall be provided throughout any fire area having a minimum occupant load of what?

A

100

BC 903.2.1.2 #2 pg 234

188
Q

A stadium press box in a Group A-5 occupancy having a maximum floor area of _________ square feet need not be sprinklered.

A

1000 square feet

BC 903.2.1.5 pg 235

189
Q

A sprinkler system is required for Group E fire areas having a minimum floor area of what?

A

12,001 square feet

BC 903.2.3 #1 pg 235

190
Q

Where woodworking operations in a Group F-1 occupancy generate finely divided combustible waste, an automatic sprinkler system is required where such operations occupy a minimum size floor area of what?

A

2,501 square feet

BC 903.2.4.1 pg 235

191
Q

In a single story ambulatory care facility, an automatic sprinkler system is required where a minimum of _____ care recipients are incapable of self-preservation at any time.

A

4

BC 903.2.2 pg 235

192
Q

An automatic sprinkler system shall be provided throughout a building with a Group M fire area located _____ stories above grade plane.

A

4 stories

BC 903.2.7 #2 pg 236

193
Q

Buildings containing which of the following residential occupancies must be sprinklered under all conditions?
A. Groups R-1 and R-2 only
B. Groups R-1, R-2 and R-4 only
C. Groups R-2 and R-4 only
D. All Group R occupancies

A

D. All Group R occupancies

BC 903.2.8 pg 236

194
Q

A building shall be fully sprinklered where the combined area of all Group S-1 fire area exceeds what?

A

24,000 square feet

BC 903.2.9 #3 pg 236

195
Q

A Group-S2 parking garage used to store commercial buses need not be sprinklered where the fire area has a maximum size of what?

A

5,000 square feet

BC 903.2.10.1 pg 237

196
Q

Where any portion of a basement is located more than a minimum of _____ feet from complying exterior openings, the basement shall be provided with an automatic sprinkler system.

A

75 feet

BC 903.2.11.1.3 pg 237

197
Q

An NFPA 13D sprinkler system is permitted to be installed in all but which one of the following uses?
A. townhouse
B. Group R-3
C. Group R-4, Condition 1
D. Group R-2

A

D. Group R-2

BC 903.3.1.3 pg 239

198
Q

Which of the following spaces requiring sprinkler system protection is not required to use quick-response or residential sprinklers?
A. light-hazard occupancies
B. sleeping units in Group R-1
C. care recipient sleeping units in Group I-2
D. sales rooms of Group M

A

D. sales rooms of Group M

BC 903.3.2 pg 240

199
Q

A minimum of ____ feet of clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.

A

3 feet

BC 903.3.3 pg 240

200
Q

Limited area sprinkler systems are only permitted to protect areas classified as what?

A

Light hazard or ordinary hazard group 1

BC 903.3.8.2 pg 241

201
Q

The manual actuation device for a fire-extinguishing system for a commercial cooking system shall be located a minimum of ______ feet and a maximum of ______ feet from the kitchen exhaust system.

A

10 feet
20 feet

BC 904.12.1 pg 243

202
Q

A court or yard that provides access to a public way for one or more exits is considered a what?

A

egress court

BC Ch 2 pg 33

203
Q

Which of the following elements is not a distinct and separate part of the means of egress?
A. exit discharge
B. exit access
C. exit
D. exit convergence

A

D. exit convergence

BC Ch 2 pg 43

204
Q

In determining the design occupant load for the sales area of a mercantile facility, the floor area shall be divided by a factor of one occupant per ______ square feet.

A

60 square feet

BC Table 1004.5 pg 279

205
Q

A 1,500 square foot woodworking shop classroom in a high school is considered to have a design occupant load of ______ persons.

A

30 persons

BC Table 1004.5 pg 279

206
Q

For areas having fixed seats and aisles, the occupant load for bench seating without dividing arms is based on one occupant for each ______ inches of seating length.

A

18 inches

BC 1004.6 pg 279

207
Q

In a fully-sprinklered Group M retail sales building having an occupant load of 3,200 occupants, the minimum total calculated means of egress width for egress elements other than stairways shall be _______ inches if an emergency voice/alarm communication system is provided.

A

480 inches

BC 1005.3.2 Exception #1

208
Q

A stairway serving 160 occupants in a fully-sprinklered Group I-2 hospital shall be a minimum of ______ inches in width.

A

44 inches

BC 1011.2 pg 297

209
Q

Multiple means of egress shall be sized so that the loss of any one means of egress shall not reduce the available capacity to less than ______ percent of the required capacity.

A

50 percent

BC 1005.5 pg 280

210
Q

When fully open, a door is permitted to project into the required width of path of egress travel a maximum of what?

A

7 inches

BC 1005.7.1 pg 281

211
Q

Up to 50 percent of the ceiling area of a means of egress may have a minimum ceiling height of ______ inches where reduced by protruding objects.

A

80 inches

BC 1003.3.1 pg 277

212
Q

At a doorway, the minimum headroom clearance below any door closer or stop shall be?

A

78 inches

BC 1003.3.1 Exception pg 277

213
Q

Other than handrails protruding from a wall or guard, the maximum projection into the travel path of a horizontal projection located between 27 and 80 inches above the walking surface shall be what?

A

4 inches

BC 1003.3.3 pg 278

214
Q

At an exterior door not required to be accessible in a Group F-1 occupancy, what is the maximum permitted elevation change?

A

7 inches

BC 1003.5 Exception #1 pg 278

215
Q

Exit signs shall be located so that the maximum distance from any point in an exit access corridor or exit passageway to the nearest visible exit sign is _______ feet, or the listed viewing distance for the sign, whichever is less.

A

100 feet

BC 1013.1 pg 302

216
Q

Externally-illuminated exit signs shall have a minimum intensity at the face of the sign of _____ foot-candles.

A

5 foot-candles

BC 1013.6.2 pg 302

217
Q

Emergency lighting facilities for means of egress illumination shall initially provide an average of _____ foot-candle along the path of egress at floor level.

A

1 foot-candle

BC 1008.3.5 pg 285

218
Q

In general, a door opening shall provide a minimum clear width of ______ inches.

A

32 inches

BC 1010.1.1 pg 288

219
Q

In a Group I-2 occupancy, means of egress doors used for the movement of beds shall have a minimum width of what?

A

41 1/2 inches

BC 1010.1.1 pg 288

220
Q

The minimum required width for door openings does not apply to storage closets less than _____ square feet in floor area.

A

10 square feet

BC 1010.1.1 Exception #3 pg 288

221
Q

At a door opening, the maximum permitted projection into the required clear width shall be ______ inches at any point between 34 inches and 80 inches above the floor.

A

4 inches

BC 1010.1.1.1 pg 289

222
Q

In other than a Group H occupancy, egress doors shall swing in the direction of egress travel where serving a minimum occupant load of what?

A

50 persons

BC 1010.1.2.1 pg 289

223
Q

A fire-rated egress door shall move to a full-open position when subjected to a maximum _____ pound force.

A

15 pound force

BC 1010.1.3 pg 289

224
Q

A revolving door shall be provided with a side-hinged swinging door located in the same wall and within _____ feet of the revolving door.

A

10 feet

BC 1010.1.4.1 #6 pg 289

225
Q

In a Group B occupancy, the minimum length of a landing at a door shall be what?

A

44 inches

BC 1010.1.6 pg 291

226
Q

Exterior landings at doors shall have a maximum slope of ______ unit vertical in 12 units horizontal.

A

1/4

BC 1010.1.5 pg 291

227
Q

Other than at sliding doors serving dwelling units, the maximum height for thresholds at doorways is what?

A

1/2 inch

BC 1010.1.7 pg 291

228
Q

In general, door handles, pulls, latches, locks and other operating devices shall be installed a minimum of ______ inches and a maximum of ______ inches above the finished floor.

A

34 inches
48 inches

BC 1010.1.9.2 pg 292

229
Q

Stairways, other than spiral stairways, shall have a minimum headroom clearance of what?

A

80 inches

BC 1011.3 pg 297

230
Q

Within an individual dwelling unit of a Group R-2 apartment building, a stair shall have a maximum riser height of _____ inches and a minimum tread depth of ______ inches.

A

7 3/4 inches
10 inches

BC 1011.5.2 Exception #3 pg 298

231
Q

Stairway handrails shall be located a minimum of _____ inches and a maximum of ______ inches above stair tread nosings.

A

34 inches
38 inches

BC 1014.2 pg 302

232
Q

The maximum permitted vertical rise of any ramp shall be?

A

30 inches

BC 1012.4 pg 301

233
Q

Where a power-operated door must be opened manually, the maximum force to set the door in motion shall be what?

A

50 pounds

BC 1010.1.4.2 pg 290

234
Q

The minimum required width for a stairway serving 75 occupants in a Group B occupancy shall be what?

A

44 inches

BC 1011.2 to 1005.3.1 pg 297 and 280

235
Q

Openings in stair walking surfaces shall be of a size that does not permit the passage of a _____ inch diameter sphere.

A

1/2 inch

BC 1011.7.1 Exception #1 pg 299

236
Q

In which one of the following occupancies having an occupant load of 40 must have at least 2 exits or exit access doorways always be provided?
A. A-2
B. B
C. F-1
D. S-1

A

D. S-1

BC Table 1006.2.1 pg 282

237
Q

Where two means of egress are required from a room in a fully sprinklered building, they shall be separated a minimum of _____ of the length of the maximum overall diagonal dimension of the area served.

A

1/3

BC 1007.1.1 Exception #2 pg 284

238
Q

Which of the following conditions is not specifically required where egress from a room passes through an adjoining room?
A. a discernable path of travel must be provided
B. the adjoining room and the area served are accessory to one or the other
C. no more than one means of egress can pass through the adjoining room
D. the adjoining room cannot be classified as Group H

A

C. no more than one means of egress can pass through the adjoining room

BC 1016.2 #2 pg 305

239
Q

Three exits or exit access doorways shall be provided from any space with a minimum occupant load of ________ and a maximum occupant load of _________.

A

501
1000

BC 1006.2.1.1 pg 281

240
Q

Up to an additional 100 feet of travel distance is available where the last portion of exit access travel occurs where?

A

on an exterior egress balcony

BC 1017.2.1 pg 306

241
Q

In a Group H-3 occupancy, the common path of egress travel is limited to a maximum of what?

A

25 feet

BC Table 1006.2.1 pg 282

242
Q

In a one-story fully-sprinklered Group F-1 occupancy, the maximum permitted exit access travel distance is 400 feet where the minimum height from the finished floor to the bottom of the ceiling or roof slab is what?

A

24 feet

BC 1017.2.2 #2 pg 306

243
Q

A corridor having a required capacity of 125 persons in a Group E occupancy shall be a minimum of _____ inches in width.

A

72 inches

BC Table 1020.2 pg 308

244
Q

A corridor in a Group B occupancy serving an occupant load of 40 persons shall have a minimum width of what?

A

36 inches

BC Table 1020.2 pg 308

245
Q

In a non-sprinklered Group M retail sales building, a corridor serving a minimum occupant load of _____ persons shall be fire-resistance rated.

A

31 persons

BC Table 1020.1 pg 308

246
Q

In a fully-sprinklered building, a corridor serving 100 persons in which of the following occupancies must be fire-resistance rated?
A. Group A-2
B. Group I-2
C. Group M
D. Group R-1

A

D. Group R-1

BC Table 1020.1 pg 308

247
Q

In a fully-sprinklered Group E occupancy, the maximum permitted length of a dead-end condition in a corridor requiring at least two means of egress is what?

A

50 feet

BC 1020.4 Exception #2 pg 309

248
Q

Utilization of corridors as return air plenums is permitted within tenant spaces having a maximum floor area of what?

A

1,000 square feet

BC 1020.5 Exception #3 pg 309

249
Q

What is the minimum required width of an egress balcony serving an apartment building where the required capacity of the balcony is 55 persons?

A

44 inches

BC 1021.1 and Table 1020.2 pg 308 and 309

250
Q

In a Group A-2 dining room having a single exit access door, the common path of egress travel is limited to a maximum of what?

A

75 feet

BC Table 1006.2.1 pg 282

251
Q

What is the maximum permitted travel distance for a Group H-1 occupancy protected by an automatic sprinkler system?

A

75 feet

BC Table 1017.2 pg 306

252
Q

A 16-foot-wide dead-end corridor in a non-sprinklered Group E high school is prohibited where the dead end is a minimum of ______ feet in length.

A

40 feet

BC 1020.4 Exception #3 pg 309

253
Q

A minimum of two exit access doorways are required in boiler rooms with a floor area exceeding a minimum of _________ square feet and any fuel-fired equipment has an input capacity greater than 400,000 BTU.

A

500 square feet

BC 1006.2.2.1 pg 281

254
Q

In a Group M occupancy, the common path of egress travel shall not exceed _______ feet from any point within a merchandise pad with an occupant load of 40.

A

75 feet

BC Table 1006.2.1 pg 282

255
Q

Where egress travel in an atrium does not occur at the level of exit discharge, a maximum of _______ feet of exit access travel distance is permitted to occur within the atrium.

A

200 feet

BC Table 1017.2 Exception a to BC 404.9.3 pg 79 and 306

256
Q

Within a dwelling unit in a Group R-2 occupancy, exit access stairways are not required to be enclosed with draft enclosure where the stairway serves a maximum of how many stories?

A

4 stories

BC 1019.3 #2 pg 307

257
Q

Required stairway identification signs shall be a minimum size of what?

A

18 inches by 12 inches

BC 1023.9.1 pg 311

258
Q

In which one of the following high-rise buildings is the installation of luminous egress path markings not required?
A. Group B
B. Group M
C. Group R-1
D. Group R-2

A

D. Group R-2

BC 1025.1 pg 312

259
Q

Where photoluminescent exit path markings are required in specific high-rise buildings, they shall be provided with not less than 1 footcandle of illumination for a minimum time period of ______ minutes prior to periods when the building is occupied and continuous during occupancy.

A

60 minutes

BC 1025.5 pg 314

260
Q

Exterior exit stairways shall be provided with a minimum fire separation distance of ______ feet from the exterior edge of the stairway to adjacent lot lines.

A

10 feet

BC 1027.5 #1 pg 315

261
Q

Stairway floor number signs shall be provided in interior exit stairways and ramps connecting a minimum of _____ stories.

A

4 stories

BC 1023.9 pg 311

262
Q

Exit passageways shall be constructed as minimum ____-hour fire ____________.

A

1-hour fire barriers

BC 1024.3 pg 312

263
Q

Where serving as a required means of egress for other than a Group I-2 occupancy, exterior exit stairways are permitted as a means of egress elements for non-high-rise buildings a maximum of ______ stories above grade plane.

A

six

BC 1027.2 pg 315

264
Q

An exterior exit stairway serving as an element of a required means of egress must be open on at least one side, with such open area a minimum of ______ square feet and located a minimum of ______ inches above the adjacent floor or landing level.

A

35 square feet
42 inches

BC 1027.3 pg 315

265
Q

Where a safe dispersal area is provided in lieu of access to a public way, the area shall be of a size to accommodate a minimum of _____ square feet for each person.

A

5 square feet

BC 1028.5 Exception #1 pg 316

266
Q

Where seating is located at a table and is adjacent to an aisle, the measurement of required clear width of the aisle shall be made to a line _______ inches away from and parallel to the edge of the table.

A

19 inches

BC 1029.13.1 pg 320

267
Q

In a 15,000-seat arena provided with smoke-protected assembly seating, the minimum width for a 1:12 ramped aisle is based on a minimum of ________ inch of width for each occupant served.

A

0.070 inch

BC Table 1029.6.2 pg 318

268
Q

The smoke level in a means of egress serving a smoke-protected assembly seating area is intended to be maintained a minimum of _____ feet above the floor of the means of egress.

A

6 feet

BC 1029.6.2.1 pg 317

269
Q

Where serving more than 5 rows, what is the minimum required clear width for stepped aisles having seating on only one side?

A

36 inches

BC 1029.9.1 #2 pg 319

270
Q

Where the foot of the aisle is more than 30 inches above the floor or grade below, a railing or fascia system at the foot of aisles in an assembly occupancy shall be a minimum of what?

A

36 inches

BC 1029.17.4 pg 323

271
Q

Where horizontal exits are used in the means of egress in a Group I-2 hospital, the horizontal exits can be used for a maximum of _________ of the required exits.

A

two-thirds

BC 1026.1 Exception #1 pg 314

272
Q

Along with other limitations, the exit discharge may occur through a vestibule, provided the vestibule has a maximum depth from the exterior of the building of ______ feet and a maximum length of _______ feet.

A

10 feet
30 feet

BC 1028.1 Exception #2.2 pg 316

273
Q

An emergency escape and rescue opening shall be located so that the bottom of the clear opening is a maximum of _______ inches above the floor surface.

A

44 inches

BC 1030.3 pg 324

274
Q

An emergency escape and rescue opening is not required from a basement without habitable spaces, provided the floor area of the basement is a maximum of what?

A

200 square feet

BC 1030.1 Exception #3 pg 323

275
Q

An emergency escape and rescue opening shall be a minimum of ______ inches in net clear opening height and a minimum of ______ inches in net clear opening width.

A

24 inches
20 inches

BC 1030.2.1 pg 324

276
Q

What door openings are not permitted in interior exit stairways?
A. Unprotected exterior openings
B. Those required for exit access to the enclosure from normally occupied spaces
C. Egress doors used for egress from the enclosure
D. Elevator doors

A

D. Elevator doors

BC 1023.4 pg 310

277
Q

In a covered mall building, the maximum distance from any point within a mall to an exit shall be what?

A

200 feet

BC 402.8.5 pg 74

278
Q

A high-rise building is defined as a building having an occupied floor located more than ______ feet above the lowest level of fire department vehicle access.

A

75 feet

Chapter 2 Definitions pg 41

279
Q

At other than the level of exit discharge from the atrium, the maximum permitted travel distance within an atrium space is what?

A

200 feet

BC 404.9.3 pg 79

280
Q

An underground building need not be divided into at least two compartments when a floor level is located a maximum of ______ feet below the lowest level of exit discharge.

A

60 feet

BC 405.4.1 pg 79

281
Q

Canopies under which fuels are dispensed shall have a minimum clearance of ______________ above the surface of the drive-through area.

A

13 feet, 6 inches

BC 406.7.2 pg 83

282
Q

Unless a permitted increase is applied, what is the minimum number of tiers permitted in a ramp-accessed single-use open parking garage of Type IIA construction?

A

10 tiers

BC Table 406.5.4 pg 82

283
Q

Smoke compartments in a Group I-2, Condition 1 occupancy shall have a maximum floor area of what?

A

22,500 square feet

BC 407.5.1 pg 86

284
Q

Doors to resident sleeping units in Group I-3 occupancies shall have a minimum clear width of what?

A

28 inches

BC 408.3.1 pg 87