JET PIPE FIRE
“TAKE ACTION - JET PIPE FIRE”
- Fuel Lever - SHUT
- Bleed Air Pressure. - ESTABLISH
- Start P/B. - ON
- Engine Selector. - AS REQUIRED
- PA - “This is the Captain, Cabin Crew to your stations”
- Motor engine - Until extinguished
- Start P/B. - OFF
- Announce - “Memory items complete”
- Call - “QRH - Jet pipe fire”.
BOTH ENGINES FLAME OUT
“TAKE ACTION - BOTH ENGINE FLAME OUT”
- IGNITION - RELIGHT
…………………………………………… - Announce - “Memory items Complete”
- call “ QRH - Both Engine Flameout”
Notes:
- Left PFD/ND remain
- VHF 1 and Transponder 1 remain.
- IRS 2 and 3 can be restored to ATT mode
- Max range = Green Dot = 3nm/1000 feet
- No hydraulics = no flaps, altn gear extension, no antiskid.
- Cabin will slowly depressurization
- APU may be available - start below 25000 ft for best chance
(SEI will show engine parameters to confirm double engine failure)
EMERGENCY DESCENT
“TAKE ACTION EMERGENCY DESCENT”
- OXYGEN MASKS. - DON
- CREW COMMS. - ESTABLISH
- ATS. - DISCONNECT
- THRUST LEVERS. - CLOSE
- SPEED BRAKE. - OUT
- ALTITUDE. -10,000 / MSA
- LVLCH. - SELECT
- SPEED. - Vmo/Mmo
ON GROUND EMERGENCY/EVACUATION
ENGINE START FAULT
- START P/B. - OFF
If alert persists
- BLEED. - ALL OFF
- FUEL LEVER. - SHUT
…………………………………………………………………………………….. - Announce - “ Memory Items Complete”
- call - “ QRH Engine Start Fault”
Note:
If the fault disappears after selecting the START PB it is an indication of a starter cut-out fault: the operation may continue.
If the fault indication persists, it is an indication that the starter valve has failed in the OPEN position. On the ground select all bleeds off to prevent the starter from overheating. When starting with an external air source, have the air supply disconnected.
NO LIGHT UP
“ SHUT”
- FUEL LEVER. - SHUT
after 30 sec.
- START PB. - OFF
…………………………………………………………………………………… - Announce - “ Memory items complete”
- Call - “QRH No Light up”
Notes:
- For a subsequent start, select RELIGHT ignition before selecting the FUEL lever to OPEN.
- Normal use of the starter is limited to 4 attempts (2 min each) with. 30 second rundown between each attempt. After 4 attempts allow at least 15 minutes cooling before further start attempts.
- If an engine fails to light up within 30 seconds of selecting the FUEL lever to OPEN, FUEL lever to SHUT.
HOT START
“SHUT”
- FUEL LEVER - SHUT
after 30 seconds
- START PB. - OFF
…………………………………………………………………………………………….. - Announce - “ Memory Items Complete”
- Call - “QRH Hot start”
N2 STAGNATION
(HUNG START)
- FUEL LEVER. - SHUT
- START PB. - OFF
……………………………………………………………………….
Announce - “ Memory Items Complete”
Call - “QRH Hot Start”
NO LIGHT UP
- FUEL LEVER. - SHUT
after 30 seconds
- START PB. - OFF
………………………………………………………………………………………..
Announce - “Memory Items Complete”
Call - “QRH Hot Start”