What is the purpose of the thermal sleeve on the PZR surge line?
Allows stagnant layer of water between piping and welds
Insulates the welds allowing them to heat up at a slower rate and thus reduces stresses
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 2?
Startup:
- Keff:*
- *≥ 0.99**
- RTP:*
- *≤ 5%**
- Tavg:*
- *≥ 350 ˚F**
- LOT 201.02 RCS*
- *
What are the piping penetrations off the hot legs?
- Loop 1:*
- *RHR “A” Suction**
- *SI “A” Recirc**
- *Sampling**
- Loop 2:*
- *RHR “B” Suction**
- *SI “B” Recirc**
- Loop 3:*
- *RHR “C” Suction**
- *SI “C” Recirc**
- *Sampling**
- Loop 4:*
- *PZR Surge Line**
- LOT 201.02 RCS*
- *
What are the piping penetrations off the cold legs?
- Loop 1:*
- *PZR Spray**
- *SI Train “A” Injection** / RHR “A” Return
- Same Penetration*
- *Normal Charging**
- Loop 2:*
- *SI Train “B” Injection** / RHR “B” Return
- Same Penetration*
- Loop 3:*
- *SI Train “C” Injection** / RHR “C” Return
- Same Penetration*
- *CVCS Alternate Charging**
- Loop 4:*
- *PZR Spray**
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 6?
Refueling:
- Keff:*
- *≤ 0.95**
- RTP:*
- *0%**
- Tavg:*
- *≤ 140 ˚F**
Fuel in the Rx vessel w/ vessel closure bolts less than fully tensioned or head removed.
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 1?
Power Operation:
- Keff:*
- *≥ 0.99**
- RTP:*
- *> 5%**
- Tavg:*
- *≥ 350 ˚F**
- LOT 201.02 RCS*
- *
What size are the pipes in the RCS?
- Cold Leg:*
- *27.5”**
- Hot Leg:*
- *29”**
- Intermediate Leg:*
- *31”**
Inside Diameter of pipes.
- LOT 201.02 RCS*
- *
How many NR hot leg and NR cold leg temperature instruments are there in each loop of the RCS?
- *3 Hot Legs**
- Located 120˚ apart for stratification purposes*
- *1 Cold Leg**
- Located downstream of RCPs (Stratification not a concern)*
Feed into Tavg and ∆T.
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 3?
Hot Standby:
- Keff:*
- *< 0.99**
- RTP:*
- *0%**
- Tavg:*
- *≥ 350 ˚F**
- LOT 201.02 RCS*
- *
What would Loop 1 RCS flow indicate if the high pressure tap on loop 1 ruptures?
All loop flows in that loop fail to zero
Loop flow consists of 1 High Pressure (Outside of elbow) and 3 Low Pressure (Inside of elbow).
↓∆P = ↓HP - LP → Flow ↓
Note:
Rupture of a Low pressure tap would result in Flow failing high on 1 of 3 flow instruments.
- LOT 201.02 RCS*
- *
What are the piping penetrations off the intermediate legs?
- Loop 1:*
- *Drain to RCDT**
- Loop 2:*
- *Drain to RCDT**
- Loop 3:*
- *Drain to RCDT**
- *CVCS Letdown**
- Loop 4:*
- *Drain to RCDT**
- *CVCS Excess Letdown**
Loop drains go to suction of RCDT pumps. Do NOT go directly to RCDT.
- Note:*
- Flange leakoff goes directly to RCDT.*
- LOT 201.02 RCS*
- *
What are the design parameters of the RCS?
- Flowrate
- RTP
- Tavg
- Pressure
- Flowrate:*
- *107,800 gpm / RCP**
- RTP:*
- *3853 MWt**
- Tavg:*
- *567 ˚F - 593 ˚F**
- 0% - 100%*
- Pressure:*
- *2485 psig**
- NOP: 2235 ± 15 psig*
Actual Tavg @ 100% is 592 ˚F
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 4?
Hot Shutdown:
- Keff:*
- *< 0.99**
- RTP:*
- *0%**
- Tavg:*
- *350 ˚F > Tavg > 200 ˚F**
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 5?
Cold Shutdown:
- Keff:*
- *< 0.99**
- RTP:*
- *0%**
- Tavg:*
- *≤ 200 ˚F**