JMurph1094 Cell Control Measures Flashcards
Propane - Used for Hot Work/Cutting/
Burning.
Used by trained staff.
Propane cannot be stored in the same cage as Acetylene.
Cages should be at least 4m from buildings and perimeter fences.
FOR EXTERNAL STORAGE CAGE
1) Incompatible gases must be separated, Propane cannot be stored with Acetylene and Oxygen cannot be stored with Inert gases.
2) Cages must have a separation distance of at least 3m, if this cannot be achieved, a 215mm blast wall which extends above the tallest cylinder must be installed.
3) To protect the cylinder base from corrosion, they should be raised off the floor slightly by means of a metal grate or the ground should be slightly sloped to allow water during any inclement weather to run away.
4) Cylinders should be protected from direct sunlight.
Vehicles should not be parked within 5m of these cages.
5) Cages should be locked with suitable warning and Ex signage (for flammables) fitted.
6) Cages should be protected from vehicle impact.
Acetylene - cylinders used for Hot Work/Cutting/
Burning.
Stored on a dedicated trolley.
Flash back arrestor.
Used by trained staff.
When cylinders are not in use, they should be safely stored outside of the building
Spares stored externally in a purpose made cage. Acetylene cannot be stored in the same cage as Propane
FOR EXTERNAL STORAGE CAGE
1) Incompatible gases must be separated, Propane cannot be stored with Acetylene and Oxygen cannot be stored with Inert gases.
2) Cages must have a separation distance of at least 3m, if this cannot be achieved, a 215mm blast wall which extends above the tallest cylinder must be installed.
3) To protect the cylinder base from corrosion, they should be raised off the floor slightly by means of a metal grate or the ground should be slightly sloped to allow water during any inclement weather to run away.
4) Cylinders should be protected from direct sunlight.
Vehicles should not be parked within 5m of these cages.
5) Cages should be locked with suitable warning and Ex signage (for flammables) fitted.
6) Cages should be protected from vehicle impact.
Oxygen cyliners used for Hot Work/Cutting/Burning.
Stored on a dedicated trolley.
Flash back arrestors.
Used by trained staff.
When cylinders are not in use, they should be safely stored outside of the building.
Inert Gases cannot be stored with Oxygen.
Spares stored externally in a purpose made cage
FOR EXTERNAL STORAGE CAGE
1) Incompatible gases must be separated, Propane cannot be stored with Acetylene and Oxygen cannot be stored with Inert gases.
2) Cages must have a separation distance of at least 3m, if this cannot be achieved, a 215mm blast wall which extends above the tallest cylinder must be installed.
3) To protect the cylinder base from corrosion, they should be raised off the floor slightly by means of a metal grate or the ground should be slightly sloped to allow water during any inclement weather to run away.
4) Cylinders should be protected from direct sunlight.
Vehicles should not be parked within 5m of these cages.
5) Cages should be locked with suitable warning and Ex signage (for flammables) fitted.
6) Cages should be protected from vehicle impact.
Argon/Co2 Mix(M21 ARC20) (Inert) cylinders used for MIG/TIG Welding.
Stored on a dedicated trolley.
Flash back arrestors.
Used by trained staff.
When cylinders are not in use, they should be safely stored outside of the building.
Inert Gases cannot be stored with Oxygen.
Spares stored externally in a purpose made cage
FOR EXTERNAL STORAGE CAGE
1) Incompatible gases must be separated, Propane cannot be stored with Acetylene and Oxygen cannot be stored with Inert gases.
2) Cages must have a separation distance of at least 3m, if this cannot be achieved, a 215mm blast wall which extends above the tallest cylinder must be installed.
3) To protect the cylinder base from corrosion, they should be raised off the floor slightly by means of a metal grate or the ground should be slightly sloped to allow water during any inclement weather to run away.
4) Cylinders should be protected from direct sunlight.
Vehicles should not be parked within 5m of these cages.
5) Cages should be locked with suitable warning and Ex signage (for flammables) fitted.
6) Cages should be protected from vehicle impact.
Diesel. 52,380L Max in an underground tank - Fuel for Murphy’s vehicles.
Tank vent.
Spill kits.
Underground interceptor.
Fuel cut off system.
Underground interceptor
Ex signage required on tank vents.
The area should be defined as a Hazardous Area with suitable EX signage in place.
Diesel. (External) 5300L at the East side of the Plant Workshop, used for Heating
Double skinned tank.
Barrier system
Spill Kits
Heating system is subject to periodic servicing, last carried out in April 2022 by OMG.
Ex signage required on tank.
Red Diesel - 34,100L Max in underground tank - Fuel for Murphy’s vehicles.
Tank vent.
Spill kits.
Underground interceptor.
Fuel cut off system.
Underground interceptor
Ex signage required on tank vents.
The area should be defined as a Hazardous Area with suitable EX signage in place.
Red Diesel. (External) 5300L at the East side of the Plant Workshop, Fuel for Murphy’s vehicles.
Double skinned tank.
Pumping equipment should be upgraded to ATEX Certified alternatives.
Barrier system
Spill Kits
The area should be defined as a Hazardous Area with suitable EX signage in place.
Oil Soaked Rags - used for Cleaning of equipment - stored in 205L drums
Drums are bunded.
Drum in the Transport Workshop is fitted with a suitable lid.
Drums are emptied regularly by a specialist contractor.
Drum in Plant Workshop should be fitted with a suitable lid.
Waste Aerosols - Waste Product
Drums are bunded.
Drum in the Transport Workshop is fitted with a suitable lid.
Drums are emptied regularly by a specialist contractor.