ICF Flashcards

1
Q

Name three types of ICF

A

Block plank and panel form

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the standard Block size?

A

419 mm (16 1/2) high and 286 mm (11 1/4 )wide and 129 mm 48 long so (16 x 48)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ICF forming starts at the

A

Corners and work towards the centre

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

And describe the bracing needed in the corners of the blocks

A

Nail two 2x6’s into an L stand it in the corner and plum and brace it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How are the Blocks braced along the rest of the wall?

A

Using vertical two by fours that are fastened to the furring strips on the blocks with screws and braces are attached to these uprights

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where do you have to make special bucks for?

A

Door and window openings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How are scaffold planks attached to the system?

A

They are attached to the vertical braces or bearers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the minimum thickness of an ICF foundation?

A

150 mm 9.15.4.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When is ICF foundation considered to be laterally supported

A

Top and bottom 9.15.4.3.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When is an ICF foundation considered to be laterally supported at the top

A

When such wall supports a solid masonry, superstructure floor joists are embedded in the top of the foundation when the floor system is anchored to the top of the foundation with an a Anchor, bolt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When is an ICF foundation considered to be laterally supported at the bottom

A

Supports backfill, not more than 1.2 mm in height, supported at footing by a sheer key and at the top by ground floor framing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Horizontal reinforcement shall consist of 110 M bar and related not more than 300 mm from the top of the wall

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If the height of the finished ground above the finished basement floor is 1.6 m in the maximum unsupported basement wall is 2.44 m what size bar and what size spacing would be called for

A

10 AM, bar at 400mm O.C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where should reinforcement be located when placed in a foundation wall, both vertical and horizontal and what would be the minimum cover?

A

Inside half the wall section and with a minimum cover at 30 mm from the inside face of the concrete 9.15.4.51B and 2B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How would a cold joint be reinforced?

A

 No less than 115 mm bar at not more than 600 mm on centre and embedded 300 mm on both sides of this joint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How should the floor Joyce be supported on ICF foundation walls?

A

Ledger boards, and anchor bolts