Ice and Rain Flashcards
Max Alt WAI ON
FL410
Max Alt WAI ON Single Bleed
FL350
Max Alt Single WAI system
FL350
In Auto WAI operates up to what FL
FL350
Manual no limit
WAI valves maintain to what temp
130 F +/- 5F
During warm up may see 150 F
What air supplies WAI
7th with 4th, high set temp of 630F
What air supplies CAI
4th stage
In Auto CAI operates up to what FL
FL350
Manual no limit
EVS widow heat in Auto turns on
When ice detected cycles heat
Gear handle UP - 1 min ON / 7 mins OFF
Gear handle DOWN - ON continuously
EVS widow heat in Man turns on
for 5 mins
4 Multifunction probes heat in Auto
On Ground
* After first engine start
* Below 60 kts - heated to 150 C
* Above 60 kts - Full heat
Airborne
* Full heat
TAT probes heat in Auto
On Ground
* Below 100 kts - OFF
* Above 100 kts - Full heat
Airborne
* Full heat
WAI Synoptic colours Blue
less than 100 F
WAI Synoptic colours Green
100 F to 180 F
WAI Synoptic colours Amber
above 180 F
o Amber inhibited for 2 mins on gnd / 4 mins in flight after Auto selected On