Electrical Flashcards
IDG Output
40 kVA, 115V AC, 400 Hz, 3-phase
Left Main AC
Left Essential TRU
Left Main TRU
AUX TRU
Emer AC Bus
* EBHA Batt
* UPS Batt
SPDS
Right Main AC
Right Essential TRU
Right Main TRU
AUX TRU (If L Main AC Bus not powered)
SPDS
60 hz converters do what
Converts 115 VAC, 400 Hz, 3 phase to - 115 VAC, 60 Hz, Single phase
Cabin sockets
o Cabin outlets rated - 3 Amps
o Galley, Lav, Baggage rated - 15 Amps
RAT Load
- Capable of 100% load up to FL 450
RAT Deployment
o Below M.935
o Maintain > 200 kts
Main Batts output
25 Volts, 53 amp/hr Ni-CAD
o 22 volts minimum
PDBs (4) Power Distribution Boxes
o Protection via CBs
o Sent to LEFT and RIGHT PDBs that then distribute the power
Left PDB in the LEER
Right PDB in the REER
o EBHA bus in tail
o AFT PDB in tail with 6 CBs for battery buses and GSB control
GCU’s (4) Generator Control Units
o 2 IDGs, APU and RAT
o Produce quality power
o In the LEER and REER
BPCUs (2) Bus Power Control Units
o Make all logical decisions for electrical distribution and protection
o Efficiently supplies power to busses
o Detects faults and lockouts if necessary
o Provides protection, power and logic to AC/DC reset switch
o Monitors external AC and DC power
o Controls the No Break Power Transfer (NBPT) function
o In the LEER and REER