APU Flashcards

1
Q

Max operating alt

A

FL 450

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Max guaranteed start alt

A

FL 370

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Max alt for starter assist

A

FL 300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If APU inop or can’t start an engine

A

FL 300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Max EGT for start

A

1050 c

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Max EGT running

A

732 c

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Min temp for gnd start

A
  • 40 c
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Max start alt

A

FL 390

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Max RPM

A

106%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Check oil levels when

A

10 - 30 minutes after shutdown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Starter limits

A

Max of 3 consecutive start attempts with a 1 minute cool down between
1 hour cooling before next full starter cycle
Or
6 successful starts with 10 min interval between starts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Min temp for ground start

A
  • 40 c
How well did you know this?
1
Not at all
2
3
4
5
Perfectly