Hydraulics Flashcards

1
Q

PDP of 100 psi nozzle 1 3/4” preconnects

A

120, 145, 180 psi = 100, 150, 200 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

PDP of 100 psi nozzle 2 1/2” preconnects

A

115, 130, 140 psi = 200, 250, 300 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

PDP of 2 1/2” preconnect with 1 1/4” smooth bore nozzle

A

95 psi = 325 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Tip pressure for smooth bore hand line

A

50 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Tip pressure for smooth bore master stream

A

80 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Tip pressure for fog tip hand line

A

100 psi or 75 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Friction loss per 100’ of 4” hose

A

2, 4, 6, 8, 10, 12, 15, 20 from 300-1000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Friction loss per 100’ of 5” hose

A

2, 2, 3, 4, 5 from 600-1000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

1/2” solid bore tip gpm

A

55 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

5/8” solid bore tip gpm

A

80 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

3/4” solid bore tip gpm

A

120 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

7/8” solid bore tip gpm

A

160 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

15/16” solid bore tip gpm

A

185 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

1” solid bore tip gpm

A

210 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

1 1/8” solid bore tip gpm

A

265 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

1 3/16” solid bore tip gpm

A

295 gpm

17
Q

1 1/4” solid bore tip gpm

A

325 gpm

18
Q

1 3/8” master stream gpm

A

500 gpm

19
Q

1 1/2” master stream gpm

A

600 gpm

20
Q

1 3/4” master stream gpm

A

800 gpm

21
Q

2” master stream gpm

A

1000 gpm

22
Q

2 1/4” master stream gpm

A

1300 gpm

23
Q

2 1/2” master stream gpm

A

1700 gpm

24
Q

2 3/4” master stream gpm

A

2000 gpm

25
Q

PDP of Blitzfire 2 1/2” preconnect with fog tip

A

160 psi = 300 gpm, 205 psi = 450 gpm

26
Q

PDP of Blitzfire 2 1/2” preconnect with solid bore tip

A

205 psi, 1 1/2” tip = 500 gpm, 210 psi, 1 3/8” tip = 500 gpm

27
Q

Pumping a sprinkler system

A

150 psi at FDC

28
Q

Relay pumping equation

A

FL + 20 psi minimum (100 psi start as default)

29
Q

Ladder supply

A

185 psi to the base, 2 supply lines to tiller truck

30
Q

Field hydraulics rule for 1 3/4” friction loss

A