Hydraulics Flashcards
What is normal system pressure?
3000 psi
What is the normal reservoir quantity?
45 - 85%
Can hydraulic quantity be accurately read without the system energized?
No
What kind of hydraulic fluid do we use?
Skydrol
What color is skydrol
Purple
If pump 1A or 2A fails, will the respective electric boost pump activate automatically?
No
When will the electric pumps (ACMPs) automatically activate?
- Respective switches to AUTO
- At least 1 generator online
- Flaps out of 0
Is system cooling provided for the hydraulic system 3?
No
How are hydraulic system 1 and 2 cooled?
Ram air in flight
or a fan in the ram air duct while on the ground blow cooling air over the shared hydraulic heat exchanger heat exchanger in the aft equipment bay
If there is an engine driven pump problem, 1A or 2A, is the associated engine required to be shutdown?
No. A shutoff valve has been positioned between the pump and the reservoir to isolate the pump from the system
When will the HYD 1 or 2 HI TEMP caution be displayed?
When the temperature exceeds 96*C
When a powered system is displayed in white on the hydraulic synoptic page, what is indicated?
The system is pressurized above 1800 psi
What is indicated when a system is displayed in amber?
The system is pressurized less than 1800 psi
What is indicated when a system is displayed in muted (dim) magenta?
The sensing system is receiving invalid data
Which pumps are not controlled by the hydraulic control data
Pumps 1A and 2A