Hydraulic Flashcards
All three hydraulic systems use ______ hydraulic fluid and operate at a nominal pressure of _____ psig
Skydrol hydraulic fluid at 3,000 psig
There are ____ engine driven hydraulic pumps, _____ electric hydraulic pumps, ____ power transfer unit, and ____ hydraulic reservoirs
There are 2 engine driven hydraulic pumps, 4 electric hydraulic pumps, 1 power transfer unit, and 3 hydraulic reservoirs
Hydraulic systems ___ and ___ are driven by an engine driven pump and backed up by ____
1 and 2
Backed up by an AC electrical pump
(T/F) The power transfer unit will not be activated if on the ground and below 50 kts
True
The PTU transfers hydraulic power between systems ___ and ___ to help operate the landing gear. When the PTU is activated it _____ (does/doesn’t) mix fluid between the two systems.
Transfers power between 1 and 2 and doesn’t mix fluid
Hydraulic system 1 provides power to the: (7)
- Left hand outboard elevator
- Upper rudder surface
- Engine 1 thrust reverse
- Multi-function spoilers pair 3/4
- Ground spoiler 2
- Outboard brakes
- Emergency parking brake
Hydraulic system 2 provides power to the: (9)
- Inboard elevator PCU
- Inboard aileron PCU
- Engine 2 thrust reverse
- Multi-function spoilers pair 5
- Ground spoiler 1
- Inboard brakes
- Nose wheel steering
- Emergency parking brake
- Landing gear
Hydraulic system 3 provides power to the: (3)
- Right outboard elevator PCU
- Lower rudder PCU
- Outboard aileron PCU
Hydraulic system 1 and 2 electric pumps turn on automatically when:
During takeoff. Flaps must be set >0. T/O thrust set or GS >50 kts.
When the engine driven pump fails
Note: The pumps will be active for at least 60 seconds and will switch off with flap retraction
Hydraulic system 3B pump activates when:
Hydraulic pump 3A fails
There is no automatic logic with hydraulic pump ____. It is either ON or OFF
3A pump
HYD X HI TEMP on EICAS means what?
HYD X OVERHEAT on EICAS means what?
Hydraulic fluid temp is 100 C or greater
Hydraulic fluid temp is 145 C or greater
If the hydraulic fluid temperature reaches ____ C the SOV will automatically close for what systems?
125 C
Systems 1 and 2
If the hydraulic fluid reaches ____ C on system 3 what happens?
125 C. Both pumps turn off automatically
HYD PUMP NOT AUTO in ____ on EICAS means what?
Blue. A hydraulic switch is not properly set for TO