HYD G RSVR OVHT Flashcards
Triggering conditions:
Fluid temperature is equal to or greater than 93 degrees.
Alert resets when the temperature reaches 88 degrees.
Initial actions:
PTU OFF
-In an overheat condition the FAULT light will remain ON even after the PTU has been switched OFF, until the fluid temperature is 88 degrees or below.
G Engine 1 Pump OFF
-FAULT light will be illuminated initially. When selected OFF the FAULT light will remain illuminated as long as the overheat condition exists.
G SYS LO PR
Fuel consumpt incr
-Triggered when the failure or combination of failures affects the nominal aerodynamic characteristics of the aircraft.
FMS predictions unreliable
-Disregard FMS fuel predictions and refer to QRH/PER-B fuel penalty tables.
STS
APPROACH PROCEDURES
HYD LO PR
If G OVHT out:
-Green Eng 1 Pump ON
If HYD not recovered:
- L/G gravity extn
- LDG dist proc apply
Fuel consumpt incr
FMS fuel predictions unreliable
Slats/flaps slow
CAT 3 single only
Inop Systems:
Green HYD SPLR 1 and 5 CAT 3 Dual N/W STRG Auto brake Normal brake L/G retract Reverser 1 Yaw damper 1