HYD B RSVR LO AIR PR Flashcards
Triggering conditions?
When the reservoir air pressure is equal to or less than 22 psi. Alert resets when pressure equal to or greater than 25 psi.
If pressure fluctuates?
Blue Elec pump off
Associated procedures.
B SYS LO PR
FUEL CONSUMPT INCR
-Triggered when the failure effects the nominal aerodynamic characteristics of the aircraft.
FMS PRED UNRELIABLE
-Disregard FMS fuel predictions and refer to QRH/PER B Fuel Penalty Factors Tables in order to find applicable fuel penalty.
Secondary failures
F/CTL
Spoiler 3 powered by the blue hydraulic system and therefore no longer available.
APPR PROC
The probability of cavitation increases with altitude.
Therefore?
It may be possible to restore the system after descending to a lower altitude.
APPR PROC
HYD LO PR
Blue Elec pump AUTO
*If system not recovered:
LDG dist proc APPLY
Fuel Consumpt Incr
FMS Pred unreliable
Slats Slow
CAT 3 single ONLY.
INOP SYS:
Blue HYD
SPLR 3
Cat 3 Dual
B ELEC PUMP