HRFPMD tools and positions Flashcards

1
Q

HRFPMD

Who selects the attack stair?

A

HRFPMD

The engine consults with the ladder company
Staircase need not have a standpipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HRFPMD

Stairways other than the ____ may be used for venting the fire floor

A

HRFPMD

Evacuation Stair

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

HRFPMD

A 1st due OV w/ No outside operations and a fire service elevator preforms what two tasks?

A

HRFPMD

Reports to lobby and places elevator in fireman service phase ll

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

HRFPMD

If the OV is involved in outside ops and the fire is above the seventh floor, the elevator cars can be operated by a member of the second truck or _______

A

HRFPMD

A member designated by the IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

HRFPMD

Which firefighters are responsible to take the KO curtain to the floor above?

A

HRFPMD

1st and 3rd due Roof FF’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

HRFPMD

2nd arriving Roof FF tools?

A

HRFPMD

Maul LSR+life belt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

HRFPMD

Who delivers the window blanket to the floor below?

A

HRFPMD

Squad

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HRFPMD

All ventilation outside the fire apartment must be limited and controlled by ___

A

HRFPMD

The IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HRFPMD

Primary means of getting to the roof?

A

Wing stairs

Isolated stairs

Any stairway in an ADJOINING building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

HRFPMD

The 2nd due LCC takes the elevator two floors below the fire floor and proceeded to the roof via the _____ stairway

A

HRFPMD

Evacuation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

HRFPMD

The first due Roof FF proceeds to the apartment above Via the ____ stairway

A

HRFPMD

Attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

HRFPMD

Horizontal Ventilation of Fire Apt controlled by _________

A

HRFPMD

Ladder officer in Fire Apt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

HRFPMD

Depending on the progress of the fire operation, this unit will usually assist or initiate searches on UPPER FLOORS and STAIRS as determined by the IC

A

HRFPMD

4th ladder company to arrive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

HRFPMD

________ shall confirm the EVACUATION stairway door(s) have been closed on the fire floor and are maintained in a closed position. This may be accomplished by positioning members on the STAIRWELL SIDE of the evacuation stairway door

A

HRFPMD

3rd ladder company to arrive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

HRFPMD

1st due OV tools?

A

HRFPMD

Halligan, hook or axe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

HRFPMD

1st due OV position?

A

HRFPMD

Conduct outside survey with Chauffeur
If Fireman serivce,operate elevator, if not
Proceed to fire floor to assist search of fire apt

17
Q

HRFPMD

1st due Roof FF position?

A

HRFPMD

Proceed to the apartment DIRECTLY ABOVE the fire via THE ATTACK STAIRWAY if possible, and gain entry. If the attack stairway is an IDLH area, team up with another member prior to proceeding to the floor above

18
Q

HRFPMD

1st du Roof FF tools?

A

HRFPMD

Halligan hydra ram, KO curtain

19
Q

HRFPMD

LCC tools?

A

HRFPMD

Whatever he or she deems necessary

20
Q

HRFPMD

LCC duties?

A

HRFPMD

Conduct outside survey with OV
Deliver LSR to floor above is roof FF calls for it

If no outside operations, WCD or LSR evolutions are indicated team up with 2nd due Chauffeur and proceed to roof

Check the condition of the hallway on the top floor, and all stairways leading to the roof for the presence of smoke and victims

21
Q

HRFPMD

If there is no blind shaft elevator to go above the fire, then take the elevator to 2 floors below the fire floor and proceed to the roof via the _____

A

HRFPMD

Evacuation stair

22
Q

HRFPMD

Who is responsible for Search of the Attack Stairwellfor FIVE FLOORS ABOVE the fire floor?

A

HRFPMD

The 2nd ladder company to arrive

23
Q

HRFPMD

Who Proceeds to the fire floor via the attack stairway and communicate with the engine and ladder company officers on the fire floor to confirm the attack and evacuation stairways.

A

HRFPMD

2nd ladder company to arrive

24
Q

HRFPMD

2nd due OV position

A

Outside ops with 2nd LCC
Fire service elevator
If no fire service, team up w/ officer on fire floor

Notify IC and operate service elevator if remote and can be safely used

25
Q

HRFPMD

1st due Roof FF tools?

A

Halligan, Maul, Life Saving Rope and Life Belt.

Proceeds to roof via ATTACK stairway

26
Q

HRFPMS

2nd due LCC tools and duties?

A

HRFPMD
whatever he or she deems necessary

Outside ops with 2nd due OV if not,
Team up with 1st LCC,
If WCD or LSR ops in progress, assist

27
Q

HRFPMD

Stairways other than the evacuation stairs may be used for venting the fire floor (T/F)

A

HRFPMD

TRUE