Brownstone tools and positions Flashcards

1
Q

Brownstones

Top floor fire
1st due OV tools?

A

Brownstones

Halligan and SAW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Brownstones

1st due Forcible entry firefighter tools?

A

Brownstones

  • Axe/Halligan(Maul/Halligan)
  • Rabbit tool
  • Flashlight HT
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Brownstones

1st arriving LCC
Position and prepare apparatus for complete coverage. When unable to complete this assignment, ___ must be notified

A

Brownstones

The IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Brownstones

When a fire denies the use of the interior stair to the occupants and there is no rear fire escape _________

A

Brownstones

Top floor VEIS is mandatory

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Brownstones

When the roof firefighter indicates no need for rescue, the chauffeur will _______

A

Brownstones

Place ladder to TOP floor for VEIS as necessary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Brownstones

When roof firefighter indicates need for a Life Saving Rope (LSR)rescue, the chauffeur shall _______

A

Brownstones

Proceed to the roof to assist

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Brownstones

When there is fire on the 3rd floor of a four-story brownstone and it can readily be seen that entry into the top floor via aerial may be negated until the fire has been darkened down. The chauffeur will wait until the possibility of lapping fire has been ______, then vent ALL WINDOWS on top floor.

A

Brownstones

Eliminated!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Brownstones

For a Top Floor Fire: A.Raise and position aerial to _______ for use by roof firefighter and OV

A

Brownstones

Roof of EXPOSURE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Brownstones

Prior to venting the top floor, the chauffeur shall communicate and coordinate with the Ladder Company Officer inside the fire area to be vented. Prior to entering an IDLH environment, the chauffeur shall team up with
the ____ or another available member

A

Brownstones

2nd due LCC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Brownstones

Once assured that laddering is not needed, or after VEIS has been completed, the chauffeur will _______

A

Brownstones

Report to their officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Brownstones

1st due OV tools @ top floor fire?

A

Brownstones

SAW & halligan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Brownstones

1sr due OV duties?

A

Brownstones

  1. Assist LCC in front
  2. Check rear
  3. Top floor fire - take saw to roof
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Brownstones

When ladder rescue is not required at the front of the building, the OV shall immediately make their way to the rear, to check for the life hazard and to _________

A

Brownstones

Vent floors within reach

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Brownstones

The 10-foot scissor ladder is a useful tool for the OV. It can be used to accomplish what five things?

A

Brownstones

Used for venting (in a closed position)
Climbing fences
Access to roof of a 1 story setback
Access to second floor for VEIS
Access to 3rd floor from roof of a setback
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Brownstones
When no rear rescue is needed and the OV is able to enter and search, they shall be teamed up with another available member. When unable to team up with another member or if unable to enter for search, the OV shall _______

A

Brownstones

Return to front of building and team up with Chaueffur for VEIS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Brownstones

Vent windows to the upper floors as directed by the _____

A

Brownstones

Ladder company officer responsible for the TOP FLOOR

17
Q

BrownstonesWhen there is No Fire Escape, after completing their roof responsibilities, the roof firefighter will descend the aerial ladder, if it is still in position at the roof, and team up with the chauffeur for ______

A

Brownstones

Top floor VEIS

18
Q

Brownstones

1st due roof FF
When the building has a rear fire escape, after completing roof ventilation duties, the roof firefighter will operate as per Ladders 3. They shall team up with the ___ (or another available member) to VEIS the fire floor and if not needed for search on that floor, proceed to VEIS the floors above

A

Brownstones

OV

19
Q

Brownstones

2nd due LCC position?

A

Brownstones

Reports to the Turntable Area of the 1st ladder Company to assist, or if necessary, team up with the chauffeur of the 1st ladder for top floor VEIS.

20
Q

Brownstones

The second due LCC Positions apparatus and place in Power Take-Off (PTO)for use by the Roof Firefighter (T/F)

A

Brownstones

TRUE
When no longer needed at the aerial or for other laddering operations on the front of the building,also goes to work where their company officer directs.

21
Q

Brownstones

2nd due OV
For a Top Floor Fire, after checking the rear, report to the roof to assist in ventilation and opening up of the roof, or
________

A

Brownstones

Goes into an exposure as directed by their officer

22
Q

Brownstones

Where conditions warrant, this member commences initial ventilation of adjoining building roofs

A

Brownstones

2nd due Roof FF

23
Q

Brownstones

________ will negate the initial use of the TL basket for roof access.

A

Brownstones

A visible life hazard

24
Q

Brownstones
When the first to arrive ladder company is a TL, the chauffeur will remain on the pedestal. Therefore the chauffeur of the 2nd to arrive ladder company ________

A

Brownstones

DOES NOT REPORT TO pedstal and

  • examines exposures
  • Assists with roof operations
25
Q

Brownstones
When the basket is used for roof access the saw and life-saving rope will be brought to the roof. The OV will wait for the completion of roof size up-before repositioning the basket to the fire floor for ventilation as coordinated with the Ladder Company Officer inside the fire area to be vented

A

Brownstones

  • ROOF –Wait
  • Fire Floor-Vent
  • Top Floor VEIS

In that Order