High-rise SOP Flashcards
Any structure with _____ or more floors and any building ______ feet above _______ _______ will be considered a high rise structure.
6, 75, grade level
This guideline provides direction for the first ______ to_______ minutes of the incident.
30-45
The fire officer or Chief officer must use his best judgement to ______ from this procedure as_______ dictate.
deviate, circumstance
The initial response to a high-rise incident will include?
2 Battalion Chief's 5 Engines 3 Ladder companies 1 Ambulance 1 Medic Supervisor 1 Safety Officer Fire alarm will dispatch the nearest ALS Engine company
On a working High-rise fire incident, what will be added to the standard 2nd alarm?
Fire shift commander EMS shift commander Safety officer Public Information Officer 3 Battalion Chiefs 2 Fire prevention officers 2 Mobile air compressors Command Bus Rehab Bus Medic Unit
On nothing Showing, the 1st engine engineer should be? And the second engine engineer?
Locating standpipe Connections
Locate a hydrant
On nothing showing, the 2nd engine should?
Go to lobby and assume lobby control
On nothing showing, where do all other responders report that do not have initial assignment?
Lobby with appropriate equiptment
On fire or smoke showing, what assignments are given to the 1st three battalion chiefs? ( In order)
1st BC- Assume IC (will become Operations Section chief when Fire
Shift commander assumes command)
2nd BC- Attack group supervisor
3rd BC- Logistics
On fire or smoke showing, 1st engine responsibilities?
Engineer - Connect to FDC, establish water supply, Take PPV to Lobby
entrance.
Crew- (Fire floor) Attack task force
On fire or smoke showing, 2nd engine responsibilities?
Engineer - Assist 1st engineer water supply(Locate hydrant),PPV to
Lobby entrance
Crew - Lobby control
On fire or smoke showing, 3rd engine responsibilities?
Engineer - Move apparatus to base, report to base manager
Crew- (fire floor) Attack task force
On fire or smoke showing, 4th Engine companies responsibility?
Engineer - Move apparatus to base and report to base manager
Crew - Establish Staging - 2 floors below the fire
On fire or smoke showing, 5th Engine responsibilities?
Engineer - Move apparatus to base and report to base manager
Crew - Extension ABOVE the fire floor, report to command
On fire or smoke showing, what are the ALS Engine’s responsibilities?
Engineer - Move apparatus to base and report to base manager
Crew - Establish Forward Rehab on the staging floor (2 floors below fire floor )
Engineers without a specific assignment may be utilized by command for the Ground Support Unit, formally known as _________________, as well as aerial operations ect.
Stairwell support unit
On fire or smoke showing, 1st ladder company assignment is?
Engineer - Position apparatus to support building, take 2 PPV’s to
Lobby
Crew - (fire floor) Attack task force
On fire or smoke showing, 2nd ladders companies assignments?
Engineer - Position apparatus to support building, 2 PPV’s to Lobby
Crew - Establish ventilation group
On fire or smoke showing, 3rd Ladders assignment?
Engineer - If necessary, position apparatus to support building, 2 PPV’s
to lobby entrance
Crew - Establish RIT (1 floor below the fire)
On fire or smoke showing, 1st medic units assignment?
Report to lobby and give ALS equipment to ALS engine
On fire or smoke showing, Medic supervisor assignment?
Establish the Medical Branch
On fire or smoke showing, Safety officers assignment?
Report to Lobby and establish Safety Officer position
What equipment should be taken by first alarm Engine crews?
High rise hose pack
1 PPV to Lobby entrance (1st and 2nd engines)
Forcible entry tools
Hand Lights, radios, accountability tags
TIC
What equipment should be taken by 1st alarm Ladder companies ?
Pike Pole Search rope or Tag lines 2 PPV's to Lobby entrance Forcible entry tools Hand lights, radios, accountability tags TIC
What equipment should The attack group supervisor and the Incident command technician bring?
Accountability board
High-rise “Go kits”
Prior to going to the reported fire floor, First in engine and ladder companies should do what 2 things?
- Collect stairwell reentry keys from knox box
2. Gather information from security/ maintenance
Prior to going to the reported fire floor, First in engine and ladder companies should do what 2 things?
- Collect stairwell reentry keys from knox box
2. Gather information from security/ maintenance
What 3 things should be reported to other responders while in stairwell?
- If evacuation is still in progress
- If there is smoke in the stairwell
- If the stairwell doors are locked
What 3 things should be reported to other responders while in stairwell?
- If evacuation is still in progress
- If there is smoke in the stairwell
- If the stairwell doors are locked
After verifying the fire floor, what should the followup report include?
- the fire floor
- the stairwell being used for attack
- request a second engine to complete the Attack Task force
- announce floors for Staging and Attack RIT
After verifying the fire floor, what should the followup report include?
- the fire floor
- the stairwell being used for attack
- request a second engine to complete the Attack Task force
- announce floors for Staging and Attack RIT
What is an Attack Task force comprised of?
Two engine crews
One ladder crew
- senior officer will be attack leader
What is an Attack Task force comprised of?
Two engine crews
One ladder crew
- senior officer will be attack leader
The Attack force has 3 components, what is the responsibility of the 3rd crew?
Stretching a back-up line
Coordinating the actions of all 3 crews
Monitoring the inline-pressure gauge
Monitoring the condition of the stairwell
Providing info. to command
* must be prepared to replace First crew, or act as RIT.
The Attack force has 3 components, what is the responsibility of the 3rd crew?
Stretching a back-up line
Coordinating the actions of all 3 crews
Monitoring the inline-pressure gauge
Monitoring the condition of the stairwell
Providing info. to command
* must be prepared to replace First crew, or act as RIT.