A test conducted using 125 percent of the rated load of the davit system.
Dynamic Load Test
A test conducted on the davit system with empty hook(s).
No-Load Operation Test
A test conducted using 100 percent of the load for which the davit system was designed to handle at the hook(s).
Rated Load Test
A test conducted using 200 percent of the rated load of the davit system.
Static Load Test
A series of tests consisting of a no-load operational test followed by static, dynamic, and rated load tests. These tests are then followed by a second no-load operational test.
System Test
A condition where the boat falls are prevented from further movement either by design or obstruction. Continued hoisting against a two-block condition will result in over stressing or failure of davit components.
Two-Blocked Falls