H MANUAL Chapter 8 Flashcards
At category 2 and 3 navy main airfields that are approved for cross staffing, in the event of a structural fire or other significant simultaneous emergency, the minimum ARFF response capability for continued flight operations shall be two ARFF vehicles and how many firefighters?
Three
What is the approved global name for all U.S. Navy and Marine Corps Air Station fire protection functions at aviation shore activities?
ARFF
At category 4, 5, and 6 main Navy airfields that are approved for cross staffing, in the event of a structural fire or other significant simultaneous emergency, the minimum ARFF response capability for continued flight operations shall be three ARFF vehicles and how many fire fighters?
Six
Airfields category requirements for support of DOD and contractor operated visiting aircraft not permanently assigned to an activity shall be based on the appropriate category (1 thru 6) whenever visiting aircraft utilize the activities airfield with 5 or more aircraft on the ground 50% of the time, and/or approximately how many landings, take offs or touch and go actions per month averaged over a 12 month period?
200 landings
The response requirement for category 4 aircraft emergencies at marine corps activities shall consist of major ARFF vehicles and a mobile water supply vehicle with a minimum combined capacity of 7,000 gallons of water and a delivery rate of how many gallons per minute?
2,500
In emergency cases where the 7230 vehicles are placed out of service for maintenance/repair, the minimum acceptable ARFF vehicle response at category 4 activities shall be how many P-19 vehicles?
FIVE
If 7230 vehicles are out of service for a period of time of more than HOW MANY HOURS the commanding officer should consider reducing flight operations for category 4 aircraft.
96 hours
Minimum on duty requirement for major aircraft firefighting and rescue vehicles necessary to meet the minimum response for U.S. Navy activities (main airfields) is how many personnel?
Three
Minimum staffing for protecting CAT-1 airfield are two personnel. U.S. Marine Corps activity minimum on-duty requirement is how many personnel?
Four
The purpose OF THE WHAT is to provide immediate response to observed, unanticipated emergencies and to control such fires until the standby alert vs. effect rescue and fire extinguishment.
IRA
The minimum required staffing for all types of major aircraft firefighting vehicles performing immediate response alert is HOW MANY FIREFIGHTERS with the exception of ARFF vehicles that require additional personnel to operate?
Two
No on person shall perform IRA duty for more than a total of how many hours in any 24 hour period.
EIGHT hours
A vehicle mounted TAU with a crew of two persons may be utilized where aircraft gross takeoff weight is how many pounds or less (gross weight category) as the IRA in lieu of a Major emergency firefighting vehicle?
14,000lbs
The point of receipt of the emergency alarm at the public safety answering point to the point where sufficient information is known to the dispatcher and applicable units are notified of the emergency is known as what?
Dispatch time
The time beginning when units are notified of the emergency to the beginning point of travel time is known as what?
Turnout time
The time that begins when units are en route to the emergency incident and ends when units arrive at the scene is defined as what?
Travel time
What is the VTOL facility that provides a designated landing area for routine use, but does not provide basing facilities such as fueling or maintenance?
Helistop
All personnel assigned to navy and marine corps shore based fire departments shall be certified by the DOD firefighter certification system in accordance with what?
DODI 6055.06-M
Although Halon 1211 is one of the most effective firefighting agents and the only “clean” agent currently in use, it has been identified as an ozone-depleting substance and has not been produced since what date?
01 January 1994
A minimum of how many live fire training evolutions shall be conducted semi-annually, per member?
Six
A daily journal shall be maintained by each aircraft firefighting and rescue organization. This journal should be a chronological listing of all pertinent events and be maintained for a minimum of how many years after the journal is completed?
3 years
Inspection of Navy aircraft firefighting operations shall be in accordance with what series?
OPNAVINST 11320.23
Where practicable all fire departments should develop an additional grid map system based on compass azimuth and mileage out to how many nautical miles?
15 nautical miles
What are used to control and extinguish fires in shadow areas in and around the fuselage that are not extinguished by the turret?
Handlines
All aviation ships certified to operate with MV-22 aircraft are required to procure and utilize wand extensions for how many pound CO2 handheld fire extinguishers?
15lb
What along with CO2 or other clean agent are the primary agent for internal engine fires and are best applied by swirling the extinguisher nozzle to fill the entire engine space with the gaseous agent?
Halon 1211
When responding to a wheel fire/hot brakes, emergency crews should approach the wheel with extreme caution in a fore or aft direction, never from the side in line with the axle. Peak temperatures may not be reached until HOW MANY MINUTES after the aircraft has come to a complete stop.
15-20 minutes
When water fog is used on a wheel assembly fire, an intermittent application of short burts (5 to 10 sec) every how many seconds should be used?
30 seconds
In aircraft mishaps where carbon/graphite or boron/tungsten fibers are suspected, helicopters should never be used to control the fire or allowed to fly or hover over the site not less than 500 feet above ground level or within how many feet horizontally?
1,000 ft
The primary flight line extinguishers are wheeled units that consist of a minimum 50 pounds of PKP (with hand-held CO2) or 150 pounds of Halon 1211 or other clean agent or how many gallons of AFFF (with hand-held)?
30 gallons
Nitrogen cylinders provided for inert-gas storage and utilized as an agent expelling shall be hydro statically tested every how many years?
5 years
Do not use Hallon 1211 on what type of fires?
Class D
Test indicate that voltages greater than how many kilovolt scan be developed on insulated metal objects from a 1 to 2 second application of CO2 from an extinguisher?
15
PKP dry chemical extinguishers are intended primRily for use in what type of fire?
Class B
Coats and trousers shall be properly sized for the wearer to ensure that the PFFPE coat and PFFPE trousers have at least a how many inch overlap of all layers so there is no gaping of the total thermal and radiant heat protection when the protective garments are worn?
2”
PFFPE shall be maintained in accordance with what manual?
NFPA 1851
Shore based fire departments/ARFF units should maintain a backup ready stock of PFFPE of approximately what percent of total unit requirements and must establish a rapid procurement procedure?
10%
What provides firefighters and rescue men with the ability to detect surface temperatures on areas exposed to fire in order to determine where additional firefighting effort needs to be concentrated or to determine if internal aircraft components continue to burn during overhaul and salvage operations?
TIC
Portable drills purchased for this use must be how many bolt or higher rating?
18 V
The P-19 has a water capacity of 1,000 gallons and the foam tank holds how many gallons?
130 gallons
The USMC twinned-agent firefighting system in use within the Fleet Marine Force is skid mounted and contains 100 gallons of AFFF premixed solution and how many pounds of dry chemical extinguishing agent PKP?
450lbs
How many Halon 1211 (20lb) portable fire extinguishers are mounted on the right side of the P-25 MFFV?
Three
A mobile water supply vehicle with at least how many gallon water capacity shall be provided at all category 2-4 USMC operated airfields (including deployed/expeditionary)?
3,000 gallons