What is defined as all ships other than carrier, fixed wing aircraft, nuclear (CVN), amphibious assault ship, general purpose ship (LHA) replenishment, or hover in-flights refueling (HIFR) operations?

A

ACS (air capable ship)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

On an LPD, who has overall responsibility for aircraft firefighting, salvage, jettison, and personnel rescue operations occurring on the flight deck and hangar?

A

Air officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In ACS other than LPD, as directed by the engineering officer, whom is responsible for accomplishing the training required to establish and maintain proficiency in the fundamentals of aircraft firefighting and rescue operations?

A

DCA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What serves to fight aircraft fires on the flight deck, affect the rescue of personnel required, and perform salvage or jettison procedures as the situation dictates?

A

Crash team

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What shall be worn by all personnel required to be outfitted in the proximity firefighting protective ensemble (PFFPE)?

A

Self-contained breathing apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Ships with aluminum flight decks must have a fully operational flush deck sprinkler system in accordance with what manual?

A

NAVAIR 00-80R-14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Who supports the scene leader, anticipating personnel and equipment requirements?

A

Background assistance leader

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Hose team leader is positioned directly behind the what and is responsible under the direction of the scene leader for his or her hose team?

A

Nozzleman

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hose outlets shall be of quantity and location to permit reaching all areas, on weather deck and below from at least how many outlets?

A

Two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Nozzles on 1 1/2” 1 3/4” saltwater lines and those used with AFFF in-line educators are how many gpm models?

A

95 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Hose downstream of the educator is typically limited to how many feet on the same deck or one deck above the saltwater outlet?

A

150 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Vari-nozzles are used in all AFFF and saltwater hose lines. Flow rates are how many gallons per minute for all 2 1/2” hoses?

A

250 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The crash and salvage tool roll shall be inspected how often (prior to flight quarters) for completeness and to ensure that tools are usable?

A

Daily

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Personnel assigned as crash, rescue, and salvage crew members to include primary and background fire teams assigned to air-capable ships and LPDs shall attend (as a team) the helicopter Firefighting Team Training once during a 24 month cycle or whenever the team experiences a greater than what percent turnover?

A

40%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A minimum of two recorded aircraft fire training drills per month shall be conducted for ships certified as class 1,2, or 3. All other class ships shall induct drills at what interval?

A

Monthly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When fire occurs on the flight and or hangar deck, word shall be passed on via the 1MC announcing system. At this time, designated personnel shall an assigned AFFF proportioning stations. Immediate communications should be established on what sound powered telephone?

A

X50J

16
Q

A fire guard shall be posted for all engine starts. Shall have a halon 1211 handheld extinguisher or a CO2 fire extinguisher with the appropriate extensions and of what length?

A

5 or 7 feet

17
Q

Hose teams shall cool weapons involved in the fire for a minimum of how many minutes or until the ordnance has been reported to be safe at a ambient temperature by EOD/weapons personnel?

A

15 minutes

18
Q

A minimum of what percent of the installed fire pump capacity shall be available in each of the yoke fire main segregations to provide adequate AFFF coverage for flight quarters?

A

75%