FR-H.1 (Heat sink) Flashcards

1
Q

FR-H.1

What is a “Dry” S/G?

When are you allowed to feed a “Dry” S/G?

A
  • L s/g (WR) < 10% [18%]
  • When no other intact S/G is available (unless depresurizing for low press feedwater injection)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

FR-H.1

What rate do you feed a Dry S/G if feed and bleed is initiated and CET are rising?

What rate do you feed a Dry S/G if feed and bleed is initiated and CET are stable/ lowering?

When L s/g > 10% what are limitations to feeding?

A
  • max rate
  • 25-100 gpm
  • feed as necessary restore H.S. (chk for SGTR)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly