E-1.1 (SI Termination) Flashcards

1
Q

E-1.1

What is the SI reinitiation criteria?

If criteria met, how is SI reinitiated?

A
  • RCS subcooling < 20 deg F
  • Lpzr not maintain > 12%
  • manually start ECCS pumps as neccesary
    • if start CCP, align injection
  • Go to E-1