Flushing Apparatus Flashcards

1
Q

Procedure for flushing a pumper

13 steps

A
  1. Full water tank
  2. Cap all intake and discharge valves
  3. Open all intake and discharge valves
  4. Open tank to pump valve
  5. Open drain valves or at a time for 20-30 seconds
  6. Close tank to pump
  7. Open drain valves again, until remaining water is drained
  8. Remove caps- intake and discharge (remove debris and check screens)
  9. Open tank to pump valve to allow water to drain for 20-30 seconds
  10. Close all intake and discharge valves
  11. Install caps
  12. Close drain valves
  13. Refill water tank
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Additional aerial platform steps

A
  • Flush rear water way intake
  • flush water with nozzles and stream shapers removed
  • flushing can also be done from a 2 1/2 inch intake water supply
How well did you know this?
1
Not at all
2
3
4
5
Perfectly