Fire Prevention (6) and Investigation (7) Flashcards

1
Q

Front street address size and font

A

At least 4” and Arabic numerals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Alley side address number size

A

At least 2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Buildings that have sprinklers and fire alarm are required to have:

A

A key box

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Propane grills and tanks are not allowed on or within how many feet of a building?

A

25ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Existing fire escapes are allowed to make up what percent of exit capacity?

A

50%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Lowest balcony on a fire escape shall not be more than how many feet high?

A

18ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Fire escapes inspected how frequently?

A

5years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Exit corridors that serve an occupant load of ____ people or more than ______ gross sq ft are to be of ____ hr resistive construction

A

10 people, 2000 sq ft and 1hr resistive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Flammable liquid storage: Can only store _____ gallons and have to be used for ______________?

A

10 gallons max for maintenance use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Class 1 standpipe (___” or more) are required in existing buildings that have an occupied floor ____ ft or more above level or Fire Dept vehicle access

A

4” or more and 50’ more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How frequently are fire hose cabinets inspected?

A

Every 5 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Fire alarm systems are required in existing residential buildings that contain more than _____ dwelling units or ____ stories above grade.

A

16 units or 3 stories above grade
Tested annually!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fire alarm pull stations require where in buildings?

A

At each point of exit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Smoke detectors are to be mounted on ceilings at least ____” from walls or on walls at least ___ to ___” below the ceiling at the top of the detector.

A

4”, and 4-12” below

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Detectors are to be located at least _____ from doors that lead to kitchens or bathrooms and at least _____ from appliances.

A

3’ and 20’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Smoke detectors that cannot be moved more than 20’ from appliances are to be equipped with a ____________ or be of the __________ type.

A

Hush button and photoelectric

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Dwellings built before 8-1-89 may have detectors _____________ or ___________.

A

Battery powered or hardwired

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Buildings built after 8-1-89 are to have detectors ________________.

A

Hardwired (and new or remodeled buildings must have a back up battery as well)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Exit signs font size:

A

Letters to be 6” high and 3/4” wide stroke

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Emergency lighting required in buildings larger than ___________ sq ft or be maze like.

A

20,000 sq ft

21
Q

Determine gross square footage of a building?

A

Measure exterior of building and multiply by number of floors.

22
Q

Door sizes:
Exit doors not less than ______ wide and _____ high.
Interior doors not less than ______ wide and ______ high.

A

Not less than 28” and 80”: exit doors
A minimum of 28” and 78”: interior doors

23
Q

Occupant load based on:

A

1 person per 5 sq ft

24
Q

Telephones or two way intercoms required every ________ floors in stairways.

A

Every 5 floors

25
Fire rated apartment doors: ______ minute fire rated and ______” solid wood or insulated steel.
20 minute fire rating and 1-3/8”
26
Operable windows above _______’ of grade or accessible from porches, stairs, etc. are required to have _________.
Above 24’ and must have security locks
27
Egress windows: all windows less than ____ stories above grade must have clear opening dimensions of ____ inches high and _____ inches wide, or ____ sq ft. Bottom of window opening be within _____ inches of floor.
Less than 4 stories, 24” high and 20” wide or 5 sq ft. Within 48” from ground up
28
Hand railings: Must be installed on stairs/porches/decks more than ______ above grade and ____ apart. Required on stairs with _____ risers or more
30 inches above grade and 9 inches apart On stairs with 4 or more risers
29
Combustible Storage: no storage in rooms containing furnace, mech or electric equipment. In other rooms maintain ____ inches from ceiling and ____ inches from sprinkler heads.
24” from ceiling and 18” from sprinkler heads. 36” clear space between utility equipment.
30
Furnace: must be capable of providing heat at _____ degrees, ___ above floor and ___ away from walls.
68° and 3’ above floor and 3’ away from wall
31
Water heater min temp?
120°
32
Sprinklers required in existing buildings basements exceeding ____ sq ft that don’t have direct exiting doors or _________ units in basement.
Exceeding 2500 sq ft or has dwelling units
33
Fire Extinguisher locations: Type 2A10BC: in halls within ____ of apartment doors Type 1A10BC: in every _______
Within 50’ of apartment doors and in every unit
34
CO detector location:
Within 10 ft of sleeping area and room where appliance is installed
35
Deadbolt locks: New size: _____ Old size but grandfathered in: _____
3/4” 5/8”
36
Bathroom ventilation: window opening to outside not less than: _____ sq ft or _____ of bathroom sq ft. Or mechanical ventilation providing _____ air changes per hr.
- 1-1/2 sq ft or 1/20th 5 air changes per hr
37
During building familiarizations if entry is denied, refusals will be followed up by:
The Office of the Fire Marshall
38
Inspections shall take place within ______ of violation notice from building familiarization.
Within 30 days
39
General Fire Watch: Uniforms worn: Arrive ______ prior to event and report to ______________.
Class B or C, arrive 1 hr prior and report to building management
40
TCF fire watch: be available to Emergency Management Team on the _____ floor.
6th floor
41
Target Center: When occupant load is below ________ or less fire watch requirement may be waved.
7,000 or less
42
School Fire Drills: - When: - Housing _____ students or more
- May and October - 20 or more students - Set up minimum of 1 shift prior. - Record school name, # of students, time of day and longest evacuation time
43
Recreational Fires: - Total fuel area being burned? - Not conducted within ______ of structure or combustible material - Barrier size? - Time of day ok to burn? - Wind speed?
- Shall not exceed 3’ diameter and 2’ high - Not within 25 feet - 6” barrier around fire - Ok between 9am and 10pm - Not in prevailing winds of 10mph
44
Minnesota Statute 299F.04 states: the chief of fire dept of each city shall investigate…
Damage exceeds $100.00 and/or arson suspected
45
Dispatch Investigator when:
- All working first alarms or greater - Fire deaths or serious injury - Known or suspected arson - Explosives/bombs - Car fire where NO DRIVER/OWNER present
46
Investigator shall determine cause of fire in ______ categories:
4 categories: - accidental - arson - undetermined -natural
47
What is CAPRS?
Computer Assisted Police Records Systems (CAPRS)
48
Evidence will be inventoried w MPD Property and Evidence room. Key labeled _____ will give access to City Hall room 33
Key PD1
49
ONLY flammable/combustible items are to be placed into inventory at Station ____.
Station 2