Fire Detection System Flashcards

1
Q

Where are the FDS wires located?

A

Engine bays and APU bay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What temp average will release the gas that trips the L/R ENG BAY T or APU BAY T cautions?

A

200C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What average temp will release the core gas that trips the FIRE warning?

A

300C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What peak temperature will release the core gas that trips the FIRE warning?

A

550C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where is the fire extinguisher located?

A

in the upper fuselage between engine bays

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many discharges are allowable from the extinguisher wired to both engine bays and the APU?

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What bus powers the electrically initiated extinguisher discharge?

A

hot batt bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FIRE EXTG caution

A

pressure in container has reduced by more than 700kPa or 15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly