FINAL TEST Flashcards
What is the minimum diameter sheave (pulley) that is required for a 900 pair cable, 2.75” in diameter, if the bend radius for a multipair in 10 x OD?
Select one:
A.
27.5 inches
B.
13.75 inches
C.
55 inches
D.
43.2 inches
The correct answer is: C
55 inches
What does this OTDR trace indicate?
Select one:
A. Non-reflective fiber break
B. Reflective end with negative loss
C. Reflective fiber break
D. Reflective end with positive loss
The correct answer is: A
Non-reflective fiber break
In a patch cord, what is the alternate colour of pair #1?
Select one:
A. Green-red
B. Blue-orange
C. Brown-slate
D. Black-yellow
The correct answer is: A
Green-red
What value of dB represents a doubling of power?
Select one:
A.
2 dB
B.
4 dB
C.
6 dB
D.
3 dB
The correct answer is: D
3 dB
A 1900 m link of singlemode outdoor fiber operating at 1310 nm has 2 mechanical splices and 2 mated connectors. The component losses are as follows:
Fiber loss = 0.5 dB/km
Splice loss = 0.3 dB
Mated pair connector loss = 0.75 dB
What is the total loss of this link?
Select one:
A.
2.30 dB
B.
3.65 dB
C.
3.05 dB
D.
4.55 dB
The correct answer is: C
3.05 dB
What will happen to channel attenuation when a 62.5 µm fiber patch cord is connected to a 50 µm fiber?
Select one:
A.
Attenuation will be higher when the source is connected to the 62.5 µm fiber
B.
Attenuation will be higher when the source is connected to the 50 µm fiber
C.
Attenuation will be higher only when operating at 850 nm
D.
Attenuation will be higher only when operating at 1300 nm
The correct answer is: A
Attenuation will be higher when the source is connected to the 62.5 µm fiber
According to ANSI-568-C.2 standard, which of the following is a required certification field-test parameter?
Select one:
A.
Resistance
B.
Impedance
C.
ACR
D.
Return Loss
The correct answer is: D
Return Loss
Installed on a CEA-310-E compliant 19” rack is the following equipment:
3(three) - Horizontal cable management panels, 19” x 1-3/4”
2(two) - Switch, 19” x 5-1/4”
2(two) - Modular pacth panels, 19” x 3-1/2”
How many rack units does all this equipment occupy?
Select one:
A.
17 rack units
B.
13 rack units
C.
7 rack units
D.
11 rack units
The correct answer is: B
13 rack units
How much shorter will the maximum permanent link length be when using 28 AWG ‘small conductor” cords with a derating factor of 92%?
Select one:
A.
82.8 meters
B.
92.0 meters
C.
99.2 meters
D.
82.5 meters
The correct answer is: A
82.8 meters
an OSP cable connecting two buildings has the following colours identifying the last pair.
Black superbinder
Violet-brown binders
Violet-slate pair
What is the minimum number of 250-pair terminal blocks and the minimum number of 25-pair connector blocks required to terminate both ends of this cable?
Select one:
A.
6 terminal blocks and 48 connector blocks
B.
15 terminal blocks and 144 connector blocks
C.
16 terminal blocks and 144 connector blocks
D.
5 terminal blocks and 48 connector blocks
The correct answer is: C
16 terminal blocks and 144 connector blocks
Which statement regarding NEXT is true?
Select one:
A.
Crosstalk is greatest at the near end (at the sender end)
B.
NEXT is only measured near the center of the link-under-test
C.
Length is a factor of NEXT
D.
NEXT measures the crosstalk on the link-under-test as the signal is measured at the receiving end
The correct answer is: A
Crosstalk is greatest at the near end (at the sender end)
According to the TIA-568.0-D standard, what is the maximum amount of conductor untwist for a Cat.3 cable?
Select one:
A.
0.5 inches
B.
0.3 inches
C.
3 inches
D.
1 inch
The correct answer is: C
3 inches
According to ANSI-568.0-D standard, what is the maximum installation pull/tensile load for a 4-pair cable?
Select one:
A.
25 lbf.
B.
100 lbf.
C.
50 lbf.
D.
75 lbf.
The correct answer is: A
25 lbf.
According to the ANSI-568.3-D standard, what is the identifying colour of a laser optimized optical fiber SC connector?
Select one:
A.
Beige
B.
Blue
C.
Aqua
D.
Green
The correct answer is: C
Aqua
According to the TIA-569-D standard, what is the maximum allowable distance between non-continuous cable supports such as “J” hooks?
Select one:
A.
4 ft
B.
5 ft
C.
3 ft
D.
2 ft.
The correct answer is: B
5 ft
What size of mechanical splice devices are required to splice a loose tube cable to a breakout cable?
Select one:
A.
125 µm - 250 µm
B.
125 µm - 900 µm
C.
250 µm - 900 µm
D.
250 µm - 250 µm
The correct answer is: C
250 µm - 900 µm
What equipment is needed to find the length of copper cable on a reel?
Select one:
A.
Wire map tester
B.
Interferometer
C.
Impedance tester
D.
Time domain reflectometer
The correct answer is: D
Time domain reflectometer
What is the minimum number of BBC’s (a.k.a., ground equalizer [GE]) required in a ten story building with two TRs per floor?
Select one:
A.
3
B.
4
C.
7
D.
10
The correct answer is: B
4
What does this OTDR trace indicate?
Select one:
A.
Reflective end with positive loss
B.
Non-reflective fiber break
C.
Reflective end with negative loss
D.
Reflective fiber break
The correct answer is: D
Reflective fiber break
An EF is located 20 meters from the exterior edge of a building. How many meters of non-FT rated outdoor fiber cable be installed into the EF?
Select one:
A.
In 5 meters of EMT
B.
In 17 meters of rigid conduit
C.
In a cable tray
D.
On J hooks
The correct answer is: B
In 17 meters of rigid conduit
When viewed from the front of the patch panel, how are the WA cables routed on a two row 48-port hinged patch panel, that hinges towards the left?
Select one:
A.
All 48 cables are routed to the right side of the patch panel
B.
All 48 cables are routed to the left side of the patch panel
C.
Cables 1 to 12 and cables 25 to 36 are routed to the left side of the patch panel. Cables 13 to 24 and cables 37 to 48 are routed to the right side of the patch panel
D.
Cables 1 to 24 are routed to the right side of the patch panel and cables 25 to 48 are routed to the left side of the patch panel
The correct answer is: B
All 48 cables are routed to the left side of the patch panel
According to ANSI/TIA-568.3-D, which is correct duplex fiber patch cord configuration?
Select one:
The correct answer is: A
What size is the PBB (TMGB)?
Select one:
A.
0.25” x 2” x 19”
B.
0.25” x 2” x variable length
C.
0.25” x 4” x variable length
D.
0.25” x 4” x 24”
The correct answer is: C
0.25” x 4” x variable length
According to the ANSI-568.3-D standard, how is a MM SC connector differentiated from a SM SC connector?
Select one:
A.
The MM connector is colour-coded orange and the SM connector is colour-coded yellow
B.
The MM connector is colour-coded grey and the SM connector is colour-coded yellow
C.
The MM connector is colour-coded beige and the SM connector is colour-coded blue
D.
The MM connector is colour-coded beige and the SM connector is colour-coded yellow
The correct answer is: C
The MM connector is colour-coded beige and the SM connector is colour-coded blue
Which of the following would be a typical size range of a 4-pair Category 5e UTP cable?
Select one:
A.
0.10” to 0.19” diameter
B.
0.31” to 0.49” diameter
C.
0.20” to 0.32” diameter
D.
0.50” to 0.75” diameter
The correct answer is: C
0.20” to 0.32” diameter
Which connector uses IDC termination technology?
Select one:
A.
110 connector
B.
N connector
C.
SC connector
D.
BNC connector
The correct answer is: 1A
10 connector
Which combination of UTP performance characteristics requires that “length” is part of the specifications (e.g. 28.7 ohms/1000 ft.)?
Select one:
A.
DC resistance, insertion loss, and impedance
B.
DC resistance, insertion loss, and capacitance
C.
DC resistance, NEXT, and insertion loss
D.
DC resistance, NEXT, and impedance
The correct answer is: B
DC resistance, insertion loss, and capacitance
How is a “Type-B’ MPO cable configured?
Select one:
A.
The fiber from position 1 goes to position 1 at the other end
B.
The fiber from position 1 goes to position 2 at the other end
C.
The fiber from position 1 goes to position 12 at the other end
D.
The fiber from position 1 goes to position 7 at the other end
The correct answer is:C
The fiber from position 1 goes to position 12 at the other end
What is indicated by the following wire map?
Select one:
A.
Split pairs
B.
Shorted pairs
C.
Reversed pairs
D.
Crossed pairs
The correct answer is: D
Crossed pairs
What splice method should be used on multipair cables, where the splices need to be maintained?
Select one:
A.
Non-pressurized splice
B.
Pass through splice
C.
Butt splice
D.
Fold back splice
The correct answer is: D
Fold back splice
What type of splice method is used if future rearrangement and maintenance is needed?
Select one:
A.
Pass through splice
B.
Foldback splice
C.
Butt splice
D.
Non-pressurized splice
The correct answer is: B
Foldback splice
What instrument is required to measure return loss per connection in an optical fiber link?
Select one:
A.
A optical source and power meter
B.
An optical TDR measurement unit
C.
An optical loss measurement unit
D.
An optical power meter
The correct answer is: B
An optical TDR measurement unit
According to ANSI/TIA-568.3-D, which statement is correct regarding Tier 2 optical fiber testing?
Select one:
A.
Tier 1 testing is an alternative to Tier 2 testing
B.
Tier 2 testing is an alternative to Tier 1 testing
C.
Tier 2 testing is done after Tier 1 testing
D.
Tier 1 testing is done after Tier 2 testing
The correct answer is: C
Tier 2 testing is done after Tier 1 testing
What is the most probable cause of the condition shown?
Select one:
A.
The two wiring standards (T568A and T568B) were mixed on this link
B.
The plug connections were made by holding one of the plug upside down
C.
This cable was wired using the USOC voice standard
D.
This cable was wired using the ANSI TP-PMD standard
The correct answer is: A
The two wiring standards (T568A and T568B) were mixed on this link
Which property of firestopping material causes it to expand when heated?
Select one:
A.
Intumescent
B.
Elastomeric
C.
Ablative
D.
Endothermic
The correct answer is: A
Intumescent
What is indicated by the following wire map?
Select one:
A.
Normal pairs
B.
Split pairs
C.
Reversed pairs
D.
Transposed pairs
The correct answer is: C
Reversed pairs
What section in the CEC would you find the rules for Conductors for a Class 2 power and Data Circuits?
A.
Section 16
B.
Section 12
C.
Section 60
D.
Section 56
The correct answer is: A
Section 16
How must a ground bus be installed?
Select one:
A.
Mounted 1-12” from non-metallic surface
B.
Mounted on insulators, spaced 2” from the mounting surface
C.
Mounted flush on mounting surface
D.
Mounted on insulators, spaced 1-1/2” from the mounting surface
The correct answer is: B
Mounted on insulators, spaced 2” from the mounting surface
When pulling a multi-pair cable, what is done to eliminate twisting?
Select one:
A.
Pull cable with a safety lanyard
B.
Pull cable with a manila rope
C.
Pull cable with a swivel
D.
Pull cable with a polypropylene rope
The correct answer is: C
Pull cable with a swivel
What is indicated by the following wire map?
Select one:
A.
Transposed pair
B.
Reversed pair
C.
Split pair
D.
Shorted pair
The correct answer is: D
Shorted pair
Which type of network topology require a central device?
Select one:
A.
Ring topology
B.
Bus topology
C.
Hybrid topology
D.
Star topology
The correct answer is: D
Star topology
What are two popular sizes of rack mounting screws?
Select one:
A.
8-32 and 10-32
B.
10-32 and 12-24
C.
6-32 and 8-32
D.
10-24 and 12-32
The correct answer is: B
10-32 and 12-24
A PoE powered WAP is relocated beyond the reach of UTP cabling. What is needed to extend the reach?
Select one:
A.
Connect the WAP with UTP to a power RF amplifier
B.
Connect the WAP with UTP to a PoE powered UTP/fiber media converter
C.
Connect the WAP to a local power source and extend the distance with coax to a remote antenna
D.
Connect the WAP to a local power source and extend the distance with UTP using UTP/coax baluns
The correct answer is: B
Connect the WAP with UTP to a PoE powered UTP/fiber media converter
A 850 m link of multimode fiber operating at 850 nm has 1 mechanical splice and 2 mated pair connectors. The component losses are as follows:
Fiber loss - 3.5 dB/km
Splice loss - 0.3 dB
Mated pair connector loss - 0.75 dB
Select one:
A.
5.08 dB
B.
4.08 dB
C.
4.33 dB
D.
4.78 dB
The correct answer is: D
4.78 dB
Given the distances of cabling need for the workstations below. How many boxes of cable are required to cable this floor section with 2 cables per workstation, including an allowance of 10% on each end?
5 Workstations @ 145 feet
6 Workstations @ 125 feet
8 Workstations @ 108 feet
2 Workstations @ 95 feet
Select one:
A.
7
B.
4
C.
6
D.
5
The correct answer is: A
7
A hybrid optical fiber loose-tube cable, with 6 strands per tube, has 24 SM strands in the first series of tubes. What are the colours of the strand and the tube of MM strand 24?
Select one:
A.
Black tube, blue strand
B.
Green tube, blue strand
C.
Black tube, white strand
D.
Green tube, white strand
The correct answer is: C
Black tube, white strand