order of installation for interior flooring finishes.
Cabinetry
Paint and Wallpaper
Wood floors
Counter Tops
Vinyl, Ceramic tile, hard surface flooring
Wood floor sanding and finishing
Appliances & Equipment
Finish Electrical — light switches, outlets, fixtures
Finish Plumbing — fixtures and fittings
Finish HVAC
Shower Doors and Mirrors
Carpet
Hardware
Drywall repairs
Cleaning
Final Paint
Final wood floor finish or touch up
order of construction/installation for interior finishes and equipment.
Cabinetry
interior doors and trim
paint and wallpaper
countertops
wood flooring
wood flooring sanding anf finishes
drwall repair
finish electrical, plumbing, hvac
appliances and equipment
cleaning
final paint
final wood floor finish
Examples of concentrated business areas
Electronic data processing facilities that function as call centers and insurance claims pre-authorization
teliphone call centers, trading floors, electrinic data processing facilities
How to solve for width of stair
Divide occupant load by 2
Multiply this number by .2 if sprinklered .3 if not sprinkled
Divide the total number of occupants by 2 for two exit stairs
200 ÷ 2 = 100
- Multiply by 0.2 inches (5.1 mm) per 1005.3.1 Exception 1 for a sprinklered building or 0.3 inches (7.6 mm) per 1005.3.1 for an unsprinklered building
100 × 0.2 = 20, which is too narrow for egress
Width of stairway landing
Should not be less than the size of the stairway served
EX Stair stairway is 44” Landing is 44”
EX Stairway is 48” Landing is 48”
If SF is more than 1,000 outlets must be places where
Same as residential no farther than 6’ (72) from wall and no father from each outlet of 12’ (144)
lighting power density of
Dining Bar lounge
Dinning cafateria
Exercise center
Office
Retail
Dining Bar lounge .9
Dinning cafateria .79
Exercise center .65
Office .79
Retail 1.06
How to determine max allowed watts
LPD X SF
Maneuvering clearances at folding and sliding doors Front approach
Perpendicular to doorway - 48”
Parallel to doorway 0
Maneuvering clearances at folding and sliding doors Pocket or hinge approach
Perpendicular to doorway - 42”
Parallel to doorway - 22
Maneuvering clearances at folding and sliding doors stop or Latch approach
Perpendicular to doorway - 42”
Parallel to doorway - 24
Proximics
intimate (0 to 18 inches [0 to 0.5 m])
personal-casual (1½ to 4 feet [0.5 to 1.2 m])
social-consultative (4 to 12 feet [1.2 to 3.7 m])
public (12 feet [3.7 m] and beyond)
Proxemics examples
Intimate in bedroom
Personal-casual Living and dinning
Social - entry
Public outside home
all receptacle outlets that serve the countertop of a kitchen in a dwelling unit, no matter where the sink is located, must be
Exceptions
GFI
It does not include standard‐height wall outlets (e.g., 15 inches [380 mm] above the floor) adjacent to the counter or outlets installed for built‐in appliances such as a garbage disposal, refrigerator, or microwave, or range. However, since 2014 NEC requires a GFCI outlet for the dishwasher.
Study Door Parts