Exam 2 Linear Acceleration Flashcards
The modulator cabinet consists of all of the following, except:
Water Cooling System
A cyclotron accelerates charged particles outwards from the center of a flat cylindrical vacuum chamber in a _________ pattern
Spiral
Electron gun function
produces electrons and injects them into the accelerator structure
Cathode
Spherically shaped structure made of a material with a high atomic number
Accelerator Structure (guide) function
accelerates electrons through multiple cavities in a linear fashion
Treatment Head
Comprised of several components designed to monitor and shape the treatment beam
Bending Magnet
Magnet system that focuses and directs the electron beam from the accelerating structure toward the treatment head
X-ray Target
placed in a electron beam to create a x-ray beam
Primary Collimators function
Shapes the beam, sets maximum field size of the beam at iso center
Beam-flattening filter
Flattens the x-ray beam exiting the target
Scattering Foil
Scatter electrons to create uniform beam of electrons for treatment
Ion Chamber measures (3)
- Dose
- Flatness
- Symmetry
Secondary collimators
Jaws of the machine, sets field size of the beam, often asymmetric
A Klystron amplifies __________ (supplied by radiofrequency driver) in machines >10 MV
microwaves
Arc (or Rotational Therapy)
radiation is delivered while the gantry moves in a arc from one point to another
Stereotactic Radiosurgery
high-dose radiation therapy in a single dose, usually cranial tumors
Stereotactic Body Radiation Therapy
high-dose radiation therapy in fractionated doses, usually outside the cranium tumors
Field in Field
technique employs small fields, often only a few centimeters in diameter with small numbers of monitor units, frequently as few as five; alternative to the use of wedged fields
Simultaneous Integrated Boost (SIB)
a differential dose per fraction is delivered to selected sub-regions during the same treatment session, leading to different total nominal doses given to target volumes in the same number of fractions
Intensity Modulated Radiation Therapy (IMRT)
advanced version of 3-D planning creating a nonuniform radiation beam allowing a better dose to the tumor while sparing more organs at risk (OAR)/normal tissue
Step and Shoot (Static IMRT)
the beam is delivered with MLC’s in a stationary position, turned off as the MLC’s move to the next segment, and then turned back on
Sliding Window (Dynamic IMRT)
the beam remains on as the MLC’s & gantry move throughout the treatment
Volumetric modulated arc therapy (VMAT)
the beam is continuously delivered while the gantry & MLC’s are both in motion
A Tomotherapy unit would best be classified as ___ delivery treatment machnie
Hellical