Normal furnace draft found in oil fired boilers is
.05 to 0.1 inches of water
Ammonia refrigerant leaks are best detected by use of a
Sulfur candle
Which one of the following types of oil burners requires lower oil admission temperatures
Steam atomizing burner
The maximum time allowed for trail for ignition on the main flame of an oil burner is shall not exceed 15 or 90 seconds depending on the btu
10 seconds
The proper amount of CO2 when using natural gas is
8%
The proper amount of CO2 when using number six oil is
14%
What attempting to determine the proper size of a boiler feed pump it is advisable to obtain one capable of delivering
One cubic foot of water for every boiler horsepower an hour
Azeolite watch her softener exchanges calcium and magnesium ions for
Sodium ions
The absorbing reagent which is used to absorb CO2
Potassium hydroxide
The absorbing reagent which is used to absorb O2
Potassium pyrrogalate
The absorbing free agent which is used to absorb Co is
Cuprous chloride
Lantern rings are used on centrifugal pumps too
Prevent air leakage into the casing
The main reason for not using water to extinguish fires on or near a power plant electrical equipment is
It may conduct electricity and cause shock
The most widely accepted test to determine the viscosity of various grades of fuel oil is the
Saybolt universal viscosity meter
A scale pocket is most often found on
The bottom of a riser
When a hydrometer made of wood or hair is made to operate a relay to automatically control humidity it is called
Hygrostate
If you were about to start a large motor-driven ammonia compressor you would
Close the suction valve and open the discharge full
Went to identical centrifugal pumps are operated in series
The head at which they operate together at a given capacity is double that for a single pump
Attend one set down transformer has 44,000 volts on the primary and 4,400 volts on the secondary if the taps are changed to reduce the number of turns in the primary by 2.5% then the secondary voltage will be most nearly
4,510 volts
Wearing rings are installed on centrifugal pumps to prevent wear and tear to
impeller
The fuel oil pressure in a mechanical atomizer burner varies from
100 to 200 PSI
On ammeter is connected to the secondary of a current transformer with the ratio of 100 to 5 if the ammeter indicates 2.0 amps the current in the primary circuit will be most nearly
40 amps
The corrosive action of the flu gases in an oil-fired boiler would be more noticeable if the flu gas temperature was increased
False
When sampling stack gases care should be taken to obtain a representative sample of the gases
True