Chief 5 Flashcards
The flame sensing device which uses flame rectification to detect a main burner gas flame senses the alternating current which has been changed from direct current by the heat of the burner flame
T
When applying a hydrostatic test to a boiler the test pressure must be held for 30 minutes
T
If a boiler operates at a pressure above 400 PSI that boiler must be provided with two water gauge glasses
T
A siphon or loop is used on a steam gauge to protect it but it is not a requirement of the new your state boiler code
F
Y type globe valves are permitted in horizontal piping but not in vertical piping
F
When the tensile strength of steel shell plates is not known it shall be taken at 55,000 lb per square inch
T
Gate valves are not suitable for throttling with a valve partially open
T
Caustic and brittleman can be defined as a weakening of boiler steel as a result of inner crystalline cracks to the Shell
T
A flame sensing device that is sensitive to ultraviolet light will not sense the red phrase emitted from a hot refractory
T
A manhole gasket should not be thicker than 1/4 inch
T
If a boiler has a minimum working pressure of 135 PSI a proper safety valve would not allow the boiler pressure to exceed 150 psi if the boiler malfunctioned and caused over firing
F
The minimum size of pipes connecting the water column to the boiler Shall be 3/4-in
F
Hydrostatic test must be conducted with water at a temperature no lower than 70° f
T
The total head of a pump is calculated by adding the suction lift and the suction head
F
The freezing point of a solution used in a brine refrigeration system is about 10 degrees Fahrenheit
F
If the capacity of a 1-in diameter pipe is 100 gallons per hour the capacity of a 5-in diameter pipe is about 500 gallons per hour
F
Asme code requires all boilers to be subjected to a hydrostatic test of the greater of 60 PSI or one and a half times the working pressure
T
A 5-ft length of one and a quarter thin pipe will equal the square foot of EDR of a cast iron radiator who’s dimensions are 9 and 3/4 wide 20 in high and 17 and a half long
T
Common glass cannot be used in the manufacturer of ultraviolet tubes as glass will screen out UV energy
T
If a successful accumulation test was conducted on a boiler whose safety valve was set at 50 psi the pressure during the test should never exceed 60 PSI
F
A “tuyere” is found use on certain types of coal-fired boilers
T
Single retorts stokers are used with either screw feed or ram feed
T
If air is cold from 80° f to 40° f it’s moisture content increases
F
Ammonia requires a greater displacement than Freon number 12 to produce one ton of refrigeration
F
A squirrel cage deduction motor has a greater air gap than a synchronous motor
T
Usually a boiler feed pump is of proper size when it is capable of delivering one cubic foot of water per hour for every boiler horsepower
T
On ammonia compressor should be started with the suction valve opened and the discharge valve closed
F
The corrosive action of the flu gases in an oil-fired boiler would be more noticeable if the flu gas temperature was increased
T
A whistling noise in the expansion valve of an ammonia system indicates on the insufficient amount of refrigerant in the system
T
The problem of scale is greater in a high pressure boiler than in a low pressure boiler
T
The difference between wet and dry bulb temperature increases as the air becomes dryer
T
It is easier to detect on ammonia leak than a Freon leak in a refrigerated system
T
On electric heater rated at 2000 watts would deliver approximately $6, 820 BTUs
T
Water is most dance at 300° f
F