EPs Flashcards
Engine Fire
ECL...Confirm...Stop Fire T Handle...Confirm...Pull IF FIRE STILL PERSISTS Fire T Handle...Twist Pull Checklist Out
Engine Residual Fire
Startup or Shutdown
ECL...Stop Eng Switch...Motor (Until PTIT under 260) Fire T Handle...Pull Pull Checklist Out
Undemanded Change in Rotor RPM and Noise
Rotor RPM High and on Ground
Both ECLs…Stop
Pull Checklist Out
Undemanded Change in Rotor RPM and Noise
Rotor RPM High and In Flight
Collective Lever…Adjust (where practical) to Contain RRPM
ECL of High Engine…Confirm…Retard
ALT Hold…Off
Pull Checklist Out
Undemanded Change in Rotor RPM and Noise
Rotor RPM Low
Collective Lever…Adjust (where appropriate) to Maintain RRPM
Both Normal Beep…Beep Up
ALT Hold…Off
Pull Checklist Out
Engine Failure, Power Loss
Audio Tone
Collective Lever…Adjust (where appropriate) to Maintain RRPM
Both Normal Beep…Beep Up
ALT Hold…Off
Pull Checklist Out
Engine N2 Governor Drive Failure
Collective Lever…Adjust (where practical) to Maintain RRPM
ECL of Affected Engine…Confirm…Retard
ALT Hold…Off
Pull Checklist Out
Emergency Engine Shutdown In Flight
ECL…Confirm…Stop
Fire T Handle…Confirm…Pull
ALT Hold…Off
Pull Checklist Out
Ground Emergency Shutdown
ECLs...Stop Fire T Handles...Pull and if fire is suspected Twist Rotor Brake...Arm...On Battery...Off Pull Checklist Out
Emergency Landing and Evacuation Drills
Water
SIC
Crash Drills ECLs...Stop T Handles...Pull Twist Rotor Brake...Arm On Battery...Off
Life Jacket…On
Flight Deck Door…Open
Engine and Rotors…Shutdown
- Order Acknowledge
- Left Raft…Launch
- Passengers Embark
- Equipment…Load
- Board Raft
Pull Checklist Out
Emergency Landing and Evacuation Drills
Water
PIC
Crash Drills ECLs...Stop T Handles...Pull Twist Rotor Brake...Arm On Battery...Off
Life Jacket…On
Riding Light…On
Engine and Rotors…Shutdown
- Right Raft…Launch
- Passenger Embarkation…Supervise
- Emergency Equipment…Take
- Board Raft
Pull Checklist Out
Emergency Landing and Evacuation Drills
Land
SIC and PIC
Crash Drills ECLs...Stop T Handles...Pull Twist Rotor Brake...Arm On Battery...Off
Evacuation (both PIC and SIC Duties)
- Cockpit Door…Jettison
- Flashlight…Take
- Exit…from cockpit emergency exit
- Ramp/Exit Panels…Open
- Passengers…Evacuate
Pull Checklist Out
Sprag Clutch Slippage
(N2 higher than Nr, loss of torque, erratic torque indications, failure of rotor speed to respond to engine beep trim inputs)
DO NOT SHUTDOWN BOTH ENGINES SIMULTANEOUSLY
Maintain Nr with ENGAGED engine
ECL (affected engine only)…STOP
After 15 seconds…ECL (engaged engine) STOP
Reset Beep Nominal
AUTO/MAN switch... MAN EMER TRIM cb... Pull Wait... 15 seconds EMER TRIM cb... In AUTO/MAN switches... AUTO
Emergency Engine Trim switch MAN back to AUTO
Affected engine ECL… Retard from FLIGHT
EMERGENCY ENG TRIM switch… Back to AUTO
Normal beep… beep down
Expect affected engine to be at min beep when ECL is returned to FLIGHT
FAS Emergency Jettison Procedures
- Overhead cargo hook panel
* EMER REL ALL switch… activate (all contents released in 10 seconds) - Close dump doors
* collective hat switch… press and release position 1 (doors close in 3 seconds)
FAS Automatic Mode (RMC) Error
- Jettison tank contents… when practical
- Open doors… press and release collective hat switch to position 2
- Close doors… press and release collective hat switch to position 1
FAS HYD PSI LOW Indicator ON
*Indicates low pressure for normal operation OPEN/CLOSE hydraulic accumulator. May reduce speed of opening and closing doors in MANUAL and AUTO mode.
If indicator stays on longer than 10 seconds, jettison tank contents when practical.
- Open doors… press and release collective hat switch to position 2
- Close doors… press and release collective hat switch to position 1
FAS E-DUMP PSI LOW Indicator ON
*Indicates low pressure for E-Dump accumulator. May reduce effectiveness of opening doors with Overhead Cargo Hook Panel EMER REL ALL switch. This does not have an effect on normal operation OPEN/CLOSE accumulator or opening and closing doors with MANUAL and AUTO mode
If indicator stays on longer than 10 seconds, jettison tank contents when practical using either Auto or Manual mode.
- Open doors… press and release collective hat switch to position 2
- Close doors… press and release collective hat switch to position 1
FAS HYD FLUID LOW Indicator ON
*Indicates low fluid for hydraulic reservoir used for normal and E-Dump accumulators. Lack of fluid can reduce effectiveness of opening/closing doors with MANUAL and AUTO mode or Overhead Cargo Hook Panel EMER REL ALL switch.
If indicator persistently stays ON at hover or during steady forward movement, jettison tank contents when practical.
- Open doors… press and release collective hat switch to position 2
- Close doors… press and release collective hat switch to position 1
If the doors DO NOT open with normal procedures:
1. Emergency Jettison Procedure