EO 1 BLOCK 4 Plant Ventilation Flashcards
MC State the purpose of Control Room Computer Room Chiller
A. Remove the heat from the Computer Room
B. Remove the Chill from the Room
C. Remove the heat from the Control Room
D. Supress the static electricity from the Computer Room
A
Which ONE of the following describes the reason that ONE Chilled Water pump
is always selected to ON?
A. To ensure adequate heating of compressor lube oil
B. To avoid compressor shutdown on low suction pressure
C. To avoid excessive cycling of the liquid line solenoid valves
D. To ensure a continuous supply of chilled water to the Computer Room Chiller
D
Which ONE of the following is NOT a function of the Control Room Emergency
Ventilation System?
A. To supply 100% outside air after 4 days of operation to limit the build-up of carbon
dioxide.
B. Ensures the ambient air temperature does not exceed allowable continuous duty
temperatures for control room instrumentation.
C. Ensures the control room will remain habitable for operations personnel.
D. Limit radiation exposure of control room personnel.
A
Which ONE of the following is a function of the Control Room Emergency
Ventilation System?
A. Ensures the Control Room will remain habitable for operations personnel.
B. Limit radiation exposure of control personnel whole body exposure to 50 REM or less.
C. To supply 100% outside air after 4 days of operation to limit the buildup of carbon
dioxide.
D. Ensures the ambient air temperature does not exceed 125 °F peak temperature for
Control Room instrumentation.
A
Which ONE of the following describes the intended design of the backup cooling
system of the Control Room Emergency Ventilation?
A. The WATER cooled condenser backs up the AIR cooled condenser if outside air
temperature is too high to provide cooling.
B. The AIR cooled condenser backs up the WATER cooled condenser if service water is
unable to provide proper cooling.
C. The WATER cooled condenser backs up the AIR cooled condenser in case a tornado
renders the air cooled condenser inoperable.
D. The AIR cooled condenser backs up the WATER cooled condenser in case the
refrigerant pressure is low.
B
The following conditions exist:
0858
* Reactor power 100%
* RCS pressure 2155 psig
* RCS Tave 582 °F
* CTMT pressure 15 psia
At0900
* Reactor power 0%
* RCS pressure 500 psig
* RCS temperature 450 °F
* CTMT pressure 24 psia
At what time should the Control Room EVS be started?
A. 0910
B. 0920
C. 0930
D. 1000
A
The plant is operating at 100% power when an SFAS SA-1 and SA-2 actuation
occurs.
The temperature in the control room is at 80°F and is rising.
Which ONE of the following actions should be performed by the Control Room
operator?
A. Verify that the Chill Water system is operating
B. Verify that the Computer Room A/C unit is operating.
C. Verify that the Control Room Emergency Ventilation System is operating.
D. Verify the Standby Control Room Ventilation system has started.
C
The plant is in Mode 2 at 2% power during a plant startup. RE 4598 AA and RE
4598 BA were BOTH declared INOPERABLE 30 minutes ago. Which ONE of
the following actions is appropriate under these circumstances?
A. Start CREVS Trains 1 and 2 in the water-cooled mode.
B. Start CREVS Trains 1 and 2 in the air-cooled mode.
C. Enter Tech Spec 3.0.3 and comply with its ACTION STATEMENT.
D. Enter Tech Spec 3.3.3.6 and comply with the provisions of Tech Spec 3.0.4.
D
During Zone 2 rounds, you notice the chilled water pump switches are in
following status:
Chilled Water Pump 1 switch in AUTO
Chilled Water Pump 2 switch in AUTO
You would:
A. AUTO is the normal Chilled Water Pump switch position for both pumps.
B. Verify that one Chilled Water Pump is running and one Chilled Water Pump is off.
C. Verify that both Chilled Water Pumps are off if chiller outlet temperature is less than 50F.
D. Contact the Unit Supervisor/Field Supervisor for direction since the Chilled Water
Pumps should not be run in AUTO.
D
Which ONE of the following systems provides makeup water to the Auxiliary
Building Chilled Water System.
A. Demineralized Water
B. Service Water
C. Domestic Water
D. Fire Protection Water
C
The most widely used refrigerant flow control used in air conditioning systems at
Davis-Besse is?
A. Capillary Tube
B. Low Side Float Valve
C. Automatic Expansion Valve
D. Thermostatic Expansion Valve
D
In a Vapor Compression Air Conditioning System, which of the following
refrigeration cycle components is considered a flow control device?
A. Filter Dryer
B. Evaporator
C. Air Cooled Condenser
D. Thermal Expansion Valve
D
In a Vapor Compression Air Conditioning System the refrigerant is in a super
heated vapor state in which of the following system sections?
A. In the air cooled condenser section only.
B. From the filter dryer to the inlet of the evaporator.
C. From the outlet of the condenser to the inlet of the evaporator.
D. From the outlet of the compressor to the inlet of the condenser.
D
In a Vapor Compression Air Conditioning System the refrigerant between the
condenser and the thermal expansion valve can best be described by which of
the the following?
A. saturated liquid
B. high pressure subcooled liquid
C. low pressure super heated gas
D. high pressure super heated gas
B
Which ONE of the following combinations describes the areas served by the
Control Room Emergency Ventilation System?
A. Cable Spread Room, Control Room
B. Control Room, Shift Manager’s Office
C. Control Room Ventilation Room, Computer Room
D. Shift Manager’s Office, Control Room Cabinet Room
B