Engine Limits Flashcards
NP1/NP2:
12-Second transient ___
Transient ___
Continuous ____
Transient ___
105-107%
101-105%
95-101%
91-95%
NR power on:
Transient ___
Continuous ____
Transient _____
101 to 107%
95 to 101%
91 to 95%
NR Power off (autorotation)
Maximum _____
Transient _____
Normal______
110%
105 to 110%
90 to 105%
Gas generator speed (NG)
12 second transient _____
Continuous______
105-106%
0 to 105%
Torque (Q)
___ -Second transient:
Dual engine above 80 knots ______
Dual engine 80 knots or below _______
Single engine ________
10 sec
100 -144%
120 to 144%
135 to 144%
Torque (Q)
Continuous:
Dual engine above 80 knots ______
Dual engine 80 knots or below _______
Single engine ________
0 to 100%
0 to 120%
0 to 135%
Turbine gas temperature TGT
12 second transient _________
2.5 minute transient (contingency power) _________
Start abort limit _________
10 minute limit _________
30 minute limit _________
Continuous _________
12 second transient ____ 903 to 949 °C
2.5 minute transient (contingency power) ____ 879 to 903°
Start abort limit ___ 851°
10 minute limit ____ 846 to 879°
30 minute limit ____ 793 to 846°
Continuous _____ 0 to 793°
Engine temperature:
30 minute limit ___
Continuous ____
Engine temperature:
30 minute limit ___ 135 to 150°
Continuous ____ -20 to 135°
Engine pressure:
5 minute limit ____
Continuous _____
Idle_____
Engine pressure:
5 minute limit ____ 100 to 120 psi
Continuous _____ 26 to 100 PSI
Idle_____ 22 to 26 PSI
Transmission temperature:
Precautionary _____
Continuous _____
Transmission temperature:
Precautionary _____ 105 to 140°
Continuous _____ -20 to 105°
NP1/NP2:
____105-107%
12-Second transient
NP1/NP2:
____101-105%
Transient
NP1/NP2:
____95-101%
Continuous
NP1/NP2:
_____91-95%
Transient
NR power on:
____101 to 107%
Transient
NR power on:
____95 to 101%
Continuous