Electrics Flashcards

1
Q

What is the minimum battery voltage required in order to proceed with a battery start?

A

23V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What type of battery does the B1900 have, how much voltage does it produced and where is it located?

A

24V NiCad battery located in the right inboard wing.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What voltage is required to automatically close the GEN TIES?

A

28V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When will the L DC GEN light illuminate?

A

When the GEN is offline

When the switch is in the off position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fault isolation protection for the triple fed bus is provided by?

A

Three 60 amp current limiters.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The BATTERY CHARGE annunciator will illuminate…?

A

When the battery is accepting a charge of more than 7 amps in 6 seconds.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A complete failure of DC power in flight will cause the loss of?

A
  • Pressurization
  • AC powered instruments
  • Cross-transfer capability
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The generators are rated at?

A

28V

300 amps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which annunciators will illuminate in the event of a grounding fault (short) on the centre bus?

A

BATT TIE OPEN

L/R GEN TIE OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If an AC Bus fails, what actions must you take?

A

AC Bus switch (failed side) off, then on.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Illumination of the green advisory light MAN TIES CLOSED indicates?

A

Manually closed generator bus ties.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Essential circuit breakers may be reset….?

A

One time after a cooling off period.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which annunciators will illuminate in the event of a major ground fault (short) on the Right Generator Bus?

A

R DC GEN

G GEN TIE OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Illumination of the caution light BATTERY CHARGE indicates?

A

Excessive charge rate on battery.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Under the following conditions what buses will be powered?

  • Fully charged battery
  • Battery Master Switch is turned on
  • Right Generator is on-line
A

All of the buses will be powered.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

With the battery fully charged and both generators on-line, what voltage should you read on the centre bus during a bus sense test?

A

0 VDC

17
Q

During engine start, if the pilot forgets to select the start switch to the OFF position, what will happen to the starter/generator?

A

Remain in the starter mode.