Electrics Flashcards
Name the five different sources of AC power
2 IDG:s
1 APU
1 Inverter
1 RAT
1 AC external power receptacle
Name three different DC power sources
1 DC external power receptacle
2 NiCd batteries
3 TRU:s
When does the led light next to the IDG selector knob illuminate?
When you get EICAS caution IDG 1(2) OIL.
This is to indicate which one to disconnect.
What is checked regarding AC power when you see ”AVAIL” in the GPU push button?
- Voltage
- Amperage
- Frequency
Which battery is used for APU starting?
Battery 2
What does it mean that a line between two components is green on the electrical synoptic page?
Voltage is sensed.
If not the line is white.
When RAT is deployed, how many seconds before you get AC power from the RAT to which bus?
After 8 seconds RAT supplies 115 VAC to the AC ESS BUS
What is the voltage and the Amperage of the two NiCd batteries?
22,8 V
27 A
EICAS warning “BATT 1(2) OVERTEMP”
What temperature is sensed in the battery?
70 degrees C
Where is SPDA 1 located?
FWD e-bay
Where is SPDA 2 located?
Center e-bay
What is the priority order regarding power sources in normal ops?
- Respective IDG
- APU generator
- GPU
- Opposite IDG
What is shed by the SPDA:s when you get EICAS advisory message “LOAD SHED”?
- Galley
- Right hand windshield heating
What does the EICAS warning “ELEC EMERCENCY” mean?
AC main buses are deenergized.
What does the EICAS caution “GPU CONNECTED” mean?
- AC/DC GPU is connected and;
- Parking brake released