APU Flashcards
Max alt for APU start?
30 000 ft
Max altitude AC power generation from APU?
33 000 ft
Max altitude for APU assisted engine start?
21 000 ft
Max altitude for using APU bleed for air conditioning?
15 000 ft
To prevent, APU from unsuccessful start, how long should you wait to start APU after EICAS is energized?
30 seconds
After APU start, when does the APU provide AC power and bleed air?
95% RPM + 3 seconds
What happens when you turn the APU MASTER SELECTOR to ON after having started a normal shut down?
Shut down is cancelled
If you get APU fire in flight, does the APU automatically shut down?
No, however on ground it shuts down automatically.
Is there any cool down period when using the emergency shut down function of the APU?
No
EICAS caution APU FAIL means…
Automatic shut down has occurred.
Restart cannot be done except if:
Shut down occurred during starting sequence and;
According to restrictions in AFM.
EICAS caution APU FAULT means…
APU Automatic shut down in flight inhibited.
Anomaly detected.
Maintenance required.