What is the main power source for the Hawk, and what is its rating?
The engine driven generator.
25kVA
What rating is the APU driven aux generator?
12kVA
What voltage does the DC system run at?
What voltage are the two DC batteries (each)?
28V
24V
State the voltage, phase and frequency of the main and aux generators.
200/115V
3 Phase
400Hz
How is the main generator cooled?
Oil cooled - it has its own oil system.
How is the aux generator cooled?
Air cooled.
Which busbar do the main and aux generators feed directly?
How are the other busbars powered?
The 200V 3-phase AC Maintained Busbar.
The AC offloadable busbar is powered directly from the AC maintained busbar.
The 26V Single Phase AC busbar is powered by the AC Maintained busbar via a 115/26V transformer.
The 28V Main DC Busbar is fed from the AC Maintained Busbar via the TRU.
The 28V ESB is fed from the 28V Main DC Busbar.
The No.1 and No.2 battery busbars are fed directly from their respective batteries.
Name the 7 busbars used in the electrical system.
3 AC
4 DC
AC:
200V Maintained
200V Offloadable
26V Single Phase
DC: 28V Main Busbar 28V Essential Services Busbar No.1 Battery Busbar No. 2 Battery Busbar
What system prioritises the power supplies?
What is the order of priority?
Interlock system.
Main Gen.
External Power
Aux Gen.
What volts and amps does the DC system run on?
28V, 250A.
How is the TRU cooled?
Fan cooled.
What busbar is the DC Voltage dial connected to?
The 28V DC ESB.
What does the VSU control?
The Bus-Tie contactor.
When will the VSU de-energise the bus tie contactor? (4)
When the engine start switch is selected to START on the ground.
When the relight sequence is initiated in flight.
When the VSU senses the 28V DC Main busbar voltage fall below 25V for more than 1 second.
When a fault condition exists.
What does the DC caption mean?
Therefore, what is powering the 28V DC ESB?
The DC bus tie contactor is opened.
The batteries.
What will happen if the GCU takes the main generator offline in flight?
The APU (and therefore Aux Gen, if switch turned on) will start automatically.
The DC caption will show until it is online.
How long may it take for the APU to start?
Up to 34 seconds.
What is the minimum voltage the landing gear requires to operate?
Which busbar does it get this power from?
21V
The 28V ESB.