ELEC Panel Flashcards

1
Q

What is the minimum battery voltage?

A

25.6V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What would a pilot do if BAT voltage is 25.5 or below on originating preflight?

A

Charge the batteries with external power by selecting BAT pushbuttons to AUTO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How long should the batteries be charged?

A

20 minutes, then recheck the voltage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Explain how to conduct the BAT check. What if it fails the test?

A
  • Select ELEC on ECAM
  • TurnBAT1&2OFFthenON
  • Check BAT charge current is < 60 amps and decreasing within 10 seconds
  • If it fails the test, wait until the end of the charging cycle, and repeat the test
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Describe the electrical power system.

A

• The electrical power system consists of a three-phase 115/200-volt 400- hertz constant frequency AC system and a 28-volt DC
• Normally, the system produces alternating current, some of which is then transformed into direct current for certain applications.
• Each of the aircraft’s three generators can supply the whole network.
• If all normal AC generation is lost, an emergency generator can supply AC
power.
• If all AC generation is lost, the system can transform DC power from the
batteries into AC power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If all AC power is lost, what happens?

A

DC power from the batteries is converted into AC.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What would be an expected indication in the GEN pushbuttons prior to engine start?

A

FAULT indication.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Define and describe an IDG.

A
  • Integrated Drive Generator

* Takes variable engine output and gives a constant output.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How would a pilot disconnect an IDG?

A

Lift the red guard and push the IDG pushbutton, being careful not to hold the pushbutton for longer than three seconds.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How would an IDG be reconnected?

A

This cannot be done by the flight crew – it is a maintenance function.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Describe the function of the BUS TIE in AUTO.

A
  • Allows a single source of power to run entire electrical system
  • Allows connection of the APU GEN or EXT power to system
  • Inhibits multiple sources connected simultaneously
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If GEN 1 fails to supply AC Bus 1, what happens?

A

Gen 2 (or APU GEN if available) powers the system through the bus tie.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How is the AC ESS bus normally powered?

A

From AC bus 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If AC BUS 1 fails, how is the AC ESS bus powered?

A

AC bus 2 automatically feed the AC ESS bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What indication will be present on the ELEC panel that AC BUS 2 is feeding the AC ESS bus?

A

AC ESS FEED ALTN light illuminated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What does a GALLEY fault light indicate?

A

At least one generator load is above 100% rated output.

17
Q

Explain the AUTO function of the GALLEY pushbutton.

A

Sheds main galley if only 1 GEN is available

18
Q

How is the BATTERY BUS normally powered?

A

DC BUS 1 through the DC tie contactor

19
Q

What buses are powered by the EMER GEN?

A
  • AC ESS BUS
  • AC ESS SHED
  • DCESSBUSbytheESSTR
  • DC ESS SHED
20
Q

What is the difference of the APU GEN FAULT and the ENG GEN FAULT?

A

Both are indicators of a line contactor open. The difference is that the ENG GEN fault may also indicate a fault detected by the ENG GCU.

21
Q

What does a BAT FAULT light indicate?

A
  • Battery charging current outside limits.

* BAT contactor opens.

22
Q

When are the batteries connected to the battery bus?

A
  • APU start
  • Battery charging
  • AC BUS 1 & 2 not powered and airspeed below 100 knots