1
Q

Where does emergency power come from?

A

A generator driven by the APU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What do the generators do?

A

Convert mech energy to elec

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where does DC power come from?

A

2 Converters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What voltage do the converters ouput?

A

28 Volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where does converter output go?

A

1 and #2 DC primary buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What provides secondary or emergency power

A

2 slab batteries

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

where does power from the slabs go?

A

battery utility bus (bub), battery bus, DC essential bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How many phases do the gen’s have?

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many priorities of power?

what are they?

A

3

main gen’s, apu gen, external power receptacle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

how are main gen’s cooled?

how is apu gen cooled?

A

oil

air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

how many gen’s are req’d for blade de-ice?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Main gen specs

A

-operates when rotor is turning.
-supplies power when NR above 85% in flight/97% ground
-1main gen can power entire aircraft with the exception of deice
must be replaced w/in 10hrs after bearing fail.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

APU Gen specs

A
  • APU must be running for generator to work.
  • Aux/backup power for backup
  • will not power windshield anti-ice while backup pump is running
  • 2gens
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

GCU specs

A
  • Voltage reg - 115/200
  • Under voltage 85-89% NR
  • Current Limiting (excessive demands disconnect gen.
  • under frequency- 93-95%NR (ground only disables by WOW)
  • feeder fault- when current transformers sense a short circuit in the feeder lines between the gen’s and the jnct boxes, the gen is disabled and disconnected from the system.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

converter takes _ phase __ VAC and makes _ VDC

A

115VAC

28VDC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

_ gen’s for blade deice

A

2

17
Q

does backup pump have priority over anti-ice when APU GEN is sole source of power

A

yes