E3 Flashcards
the distance a crane must be from power lines if the lines are charged with 750-75,000 Volts?
3m
the distance a crane must be from power lines if the lines are charged with 75,000-250,000 Volts?
4.5
the distance a crane must be from power lines if the lines are charged with over 250,000 Volts?
6m
turnbuckles have witch threads and a sleeve?
left hand and right hand threads
what is a turnbuckle Jaw end?
a U joint with a pin
at what angle are eye bolts able to with stand?
45 degrees but no more
what is the throat of a shackle?
the round part for the rope end
when are shackles used?
when two or more ropes are place on a hook
what must you never do with a shackle?
replace the Pin with an ordinary bolt
the pin end of a shackle should always be the ___ end
hook end never sideways
the space between cable clips is how far?
6-7 rope diameters
correctly installed cable clips reduce the breaking strength by ___ if correct it is increased by ___
20% less and 50% more
what should be used for transporting steel pipe by crane?
Choker hooks and if long pips then a spreader beam
what is a bridal hitch?
two or more ropes or slings used too support the load
if using 4 ropes what is lifting the load?
only two the other two are to stablize