Engine
Cummins 450 BHP, 10.8 Liter, ISM with Electronic Controls
Transmission
Allison EVS 4000 6-Speed Automatic World Transmission
The MDT will continue to draw electrical current (_____) even though the battery master switch is turned OFF.
approximately 7 to 8 amps
A remote ON/OFF switch controls the power to the Kenwood, 800 radio and MDT. It is located in the compartment below the ____.
center jumpseat
Maximum inlet restriction for a new air cleaner is ___ H2O. If the gauge reads 25” H2O, check for restrictions.
10”
Operating range is ___.
1200 to 2100 RPM.
The best fuel economy is delivered between ____.
1200 – 1800 RPM.
The ISM also delivers greater torque and pulling power at ____.
lower RPM
Gear 1
2100 rpm / 14 mph
Gear 2
2100 rpm / 26 mph
Gear 3
2100 rpm / 36 mph
Gear 4
2100 rpm / 54 mph
Gear 5
2000 rpm / 66 mph
Gear 6
1700 rpm / 66 mph
If there is no oil pressure indicated within ___ seconds, stop the engine and check the lubricating system.
10 to 15