Demolition Safety and Transportation (Chapter 3) Flashcards
- For calculating MSD, When do you refer table 6-2?
When charge weight is more than 27 lbs and less than 500 lbs
- In temporary storage, how explosive should be stack?
Explosive should:
Weigh no more than 500 lbs per pile
Placed no less than 140 feet apart
- What is minimum distance required to prepare electric blasting cap?
At least 155m from energetic source
- To ensure circulation of air, what is minimum distance from top of stack to ceiling or cover?
No less than 18 inches
- To ensure circulation of air, what is minimum distance from bottom of stack to earth flooring?
No less than 3 inches
- Where are blasting caps stored during transportation?
Transfer in separate location from the explosives
How do you calculate MSD when charge weight is more than 500 lbs?
Meters = 100 x cube root of N.E.W
Feet =300 x cube root of N.E.W
- What is minimum requirement for time fuse test burn, and how many times should be conducted?
At minimum 3 ft test burn. Do not use the first or last 6” of time fuse from a new or partially used roll (moisture) Book answer is every 24 hrs. However it should be conducted every hour. Upon completion of test, mark roll with DTG, then tie half knot in non-working end
- Premature detonation of electric blasting caps may be include by
Radio Radar TV signal Lightning Static electricity
- What are the some considerations in demolition safety?
a) Maintain Control of all initiation source at all times (i.e. RAMS transmitter, electrical blasting machines, etc.)
b) Suspend blasting operations during electrical storms
- What is the first step you take when conducting a continuity check?
Ground yourself
- What is SADD?
Rules for storing explosives: Safety Accessibility Dryness Drainage
- How many people requires to conduct explosive transportation?
Use only minimum number of personnel necessary to accomplish the mission
- How many fire extinguishers you must have when you transporting explosive and what are they?
2, Class B and C
- What is the MSD for charges that less than 27 lbs?
300 meter
- Can you destroy blasting cap with burning method?
NO. Blasting cap destroy by only detonation
- What is formula for DET Cord N.E.W?
Length in feet x 54 grains per foot x RE Factor = total grains of explosives
Grains / 7000 = NET EXPLOSIVE WEIGHT IN LBS
- When placing electrical blasting caps in a metal container, how much overlap should be on the lid ?
Minimum ½ inches overlap
- How long should you wait to clear a nonelectric misfire and electric misfire?
Non-electric: 30 minutes
Electric: Immediately
- What is the preferred method of disposing of explosive?
Burning
- If it is only means, can you use BLASTING CAPS underground?
No, Do not use blasting caps underground, use DET Cord or m151/m152 boosters
- When burning explosive what must you do?
Calculate Minimum Safety Distance
Ensure stacked pules will not exceed 2000 lbs or more than 3 inches thick