Demolition Safety and Transportation (Chapter 3) Flashcards
- For calculating MSD, When do you refer table 6-2?
When charge weight is more than 27 lbs and less than 500 lbs
- In temporary storage, how explosive should be stack?
Explosive should:
Weigh no more than 500 lbs per pile
Placed no less than 140 feet apart
- What is minimum distance required to prepare electric blasting cap?
At least 155m from energetic source
- To ensure circulation of air, what is minimum distance from top of stack to ceiling or cover?
No less than 18 inches
- To ensure circulation of air, what is minimum distance from bottom of stack to earth flooring?
No less than 3 inches
- Where are blasting caps stored during transportation?
Transfer in separate location from the explosives
How do you calculate MSD when charge weight is more than 500 lbs?
Meters = 100 x cube root of N.E.W
Feet =300 x cube root of N.E.W
- What is minimum requirement for time fuse test burn, and how many times should be conducted?
At minimum 3 ft test burn. Do not use the first or last 6” of time fuse from a new or partially used roll (moisture) Book answer is every 24 hrs. However it should be conducted every hour. Upon completion of test, mark roll with DTG, then tie half knot in non-working end
- Premature detonation of electric blasting caps may be include by
Radio Radar TV signal Lightning Static electricity
- What are the some considerations in demolition safety?
a) Maintain Control of all initiation source at all times (i.e. RAMS transmitter, electrical blasting machines, etc.)
b) Suspend blasting operations during electrical storms
- What is the first step you take when conducting a continuity check?
Ground yourself
- What is SADD?
Rules for storing explosives: Safety Accessibility Dryness Drainage
- How many people requires to conduct explosive transportation?
Use only minimum number of personnel necessary to accomplish the mission
- How many fire extinguishers you must have when you transporting explosive and what are they?
2, Class B and C
- What is the MSD for charges that less than 27 lbs?