Definitions Flashcards
The unobstructed vertical distance through air bn the lowest point of the water supply outlet and the flood level rim of the fixture of device into which the outlet discharges, is what?
Air Gap
A backflow preventer assembled as a unit w/ properly located / approved shutoff valves and test cocks so the device can be approved by testing agency and accepted to the AHJ, is what?
Approved Testable Backflow preventer
Backflow protection provided for a section of a piping system w/ potable / non-potable connections (that may or may not be considered CC) downstream of a backflow preventer, is the definition of?
Area Protection
Atmospheric vacuum breaker (AVB) is defined as what?
A vacuum breaker designed to be under pressure only when water is being drawn from the water supply system / short, intermittent periods of time.
Any water supply, on or available to the premises, other than the primary potable water supply, is what?
Auxiliary Water Supply
A flowing back or reversal of the normal direction of the flow
Backflow
A device or method that prevents backflow
Backflow preventer
a pressure higher than the supply pressure
Back pressure
Backflow caused by pressure below atmospheric in the supply system
Back siphonage
A fabricated loop of piping connected to the potable to the potable water supply that rises at least 10.7 m (35’), at its uppermost point, above the highest fixture it serves
- this guy only protects against back siphonage only
Barometric loop
The level of submergence at which a back siphonage preventer ceases to prevent back siphonage
Critical Level
A backflow preventer consisting of 2 approved double check valve, set in parallel, equipped w/ a meter on the bypass line for the purpose of detecting small amounts or water leakage or unauthorized use.
- Are used to protect against back siphonage + back pressure
Double Check Detector Assembly
A backflow preventer that consists of 2 force - loaded, indy acting check valves + 2 resilient - seated shut off valves located at each end of the DCVA backflow preventer and is fitted w/ resilient - seated test cocks
- designed for use under con’t pressure
Double check valve assembly (DCVA)
A backflow preventer that consists of 2 indy acting force loaded, soft - seated check valves in series.
They do not have a relief port or test cocks
Designed for use under con’t pressure
Dual Check Valve (DuC)
A backflow preventer that consists of 2 indy acting check valves separated by an intermediate chamber w/ an atmospheric port
- Used under con’t pressure
Dual check valve w/ atmospheric port (DCAP)