CVCS (Seal Injection / Seal Return) Flashcards
1
Q
Limits on RCP seal flow
ITS, Normal, Expanded
A
- ITS limit: >6gpm
- Normal Band: 8-13gpm
- Expanded Band: 6-20gpm (Used during transients)
2
Q
Seal flow adjusted by?
A
-CVC-297 āA,B,Cā
3
Q
CVC-303 A, B, C
Seal Leakoff Vlaves
A
- Seal return from #1 RCP seals
- Fail open
4
Q
Seal return flow
normal?
max?
A
- Normal: 9gpm total
- Maximum : 40gpm total
5
Q
CVC-381
Seal Water Return Valve
A
- Motor operated (powered from MCC-5)
- Shuts on Phase B