CVCS (Seal Injection / Seal Return) Flashcards

1
Q

Limits on RCP seal flow

ITS, Normal, Expanded

A
  • ITS limit: >6gpm
  • Normal Band: 8-13gpm
  • Expanded Band: 6-20gpm (Used during transients)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Seal flow adjusted by?

A

-CVC-297 ā€œA,B,Cā€

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

CVC-303 A, B, C

Seal Leakoff Vlaves

A
  • Seal return from #1 RCP seals

- Fail open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Seal return flow
normal?
max?

A
  • Normal: 9gpm total

- Maximum : 40gpm total

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

CVC-381

Seal Water Return Valve

A
  • Motor operated (powered from MCC-5)

- Shuts on Phase B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly