CVCS (BAST, Makeup, and Transfer System) Flashcards
1
Q
BASTs
A
- 2 tanks
- TRM requirement to have enough boric acid to borate to cold shutdown (>3080gal, 20,000-22,500ppm,>145F)
2
Q
A Boric Acid Transfer Pump, and 2 immersion heaters for each Storage Tank.
Power supplies?
A
- Tank A- MCC-5
- Tank B-MCC-6
3
Q
Modes of operations
A
- Automatic
- Borate
- Dilute
- Alternate Dilute
4
Q
MOV-350
Emergency Boration Vlave
A
- Powered by MCC-5
- Lines up BA pump directly to Charging Pump suction for Emergency Boratian
- normally 65gpm
5
Q
Heat Tracing power supplies and why?
A
- ITS min temp is 145F, boric acid starts to solidify
- Powered by MMC-6 or 5 (Primary/Secondary)
6
Q
Boric acid filter
A
- Located in CCW pump room
- Max dp is 20psid
- can be bypassed for cartridge replacement
7
Q
Batching tank and acid blender
A
- 2 floor aux building batch tank
- Blender promotes mixing of boric acid solution and primary water, shortens the pipe length required to homogenize the mixture. Located in CCW pump room
8
Q
Primary Water Pumps
A
- A-MCC-1
- B-MCC-2