Core Flood Flashcards
List the acceptance criteria for ECCS.
Hydrogen <= 1% Oxidation of cladding <=17% Temperature of cladding <=2200F Cool-able geometry Keep cool (Long Term)
Why do we call Core Flood a passive system?
No outside power is required
No outside actuation signal is required
Nitrogen pressure provides the driving force
What is required for ONE train of ECCS?
ONE train of HPI
ONE train of LPI
BOTH CFTs
What are the 3 phases of a LOCA?
- ) Blowdown- rapid loss of coolant
- ) Refill- both CFT discharge
- ) Reflood- HPI & LPI injection
What is the Function of CFT System?
Core Protection after intermediate to large breaks
Passive injection when RCS <600#
Both tanks cover 3/4 of core
What is the required CFT boron concentration?
2270-3500 ppm
List ECCS Acceptance Criteria
- Peak clad temp. <= 2200 deg F
- Clad oxidation <= 17% of clad thickness
- Max H2 generation <= 1% of all that could be generated
- Maintain coolable core geometry
- Provide long-term cooling
Core Flood Tank Tech Specs with 1 hr Conditions
Two CFTs operable
Modes 1 & 2, Mode 3 with RCS press >800psig
Condition: 1 CFT inop for reasons other than boron
Action: Restore to operable status
Completion Time: 1 hour
• Level: 12.6 to 13.4 feet • Pressure: 560 to 640 psig • MOV Discharge Valve de-energized open (TRM) One of Two pressure and One of Two level instrument channels per CFT
Basis for pressure and level limits.
640# = sufficient volume to refill 560# = sufficient pressure to fully inject in time
- 4’ = enough N2 to fully inject contents
- 6’ = sufficient volume to refill
Horn and lights if CFT MOV closed and RCS press >____psig
750psig
In normal ops, MOVs opened when raising RCS press @ _______ psig.
700-730 psig
In normal ops, CFT MOVs required to be open prior to ____ psig RCS press.
800 psig
In normal ops, CFT MOVs required to be closed prior to ____ psig RCS press.
700 psig
Describe interlocks between CFT outlet valves and DH valves.
Which CFT to which DH valve?
A CFT interlocked with CV-1050 and B CFT interlocked with CV-1410
Decay heat iso valve will _____ if CFT outlet valve is removed from 100% _____ seat.
Close, closed