CODES & REGULATIONS - Accessibility Laws, Codes and Guidelines Flashcards
ADA
Americans with Disabilities Act - law that prohibits discrimination based on disablity
BOMA
Building owners and managers Association - Professional organization thats for commercial real estate professionals
FHA
Fair housing act - law that prohibits housing discrimination on the basis of race, color, religion, sex, disability, familial status and nation orgin
HUD
US department of housing and urban development
ADA accessible guide lines
Includes all employee work area and temporary construction that is open to the public ( area not required include: temporary construction facilities, non occupiable service areas, toll booths, water slides…
dimensional standards: Wheelchair passage width 2 wheelchair passage width headroom turning space clear floor space changes in levels doors door clearances accessible route cross slope ramps: slopes, width, length, landing, 2 handrails handrail height handrail cross section handrail extension stair ways walkways curb cuts car parking space van parking space parking space location 7-50 car lot 51-100 car lot 101-150 car lot
Wheelchair passage width - 32” clear point 36” clear contin.
2 wheelchair passage width - 60” clear min
headroom - 80” min
turning space - 5’ circle min
clear floor space - 2’-6” wide x 4’-0” long min
changes in levels - 1/4” max w/o treatment
beveled edge - 1/4” -1/2” w 1:2 max slope
Requires ramp - 1/2” or more
doors - 32” clear min
door clearances - 1’6” clear on pull side
accessible route cross section - 1:50 max
ramp - slope (1:20 min to 1:12 max) width (3’ wide) length (30’ max w/o landing) landings (5’ at each end) 2 handrails( if rise is +6” or run is 72”
handrail height - 34” min - 38” max
handrail cross section - 1 1/4” - 2” ans 1 1/2” clear from wall
handrail extension - 12” at top and 12” +1 tread bottom
stair ways - 48” clear between handrails
walkways - 1:20 max (5%)
curb cuts - 3’ sides 1:10 max
car parking space - 9- wide with 5’ wide aisle
van parking space - 11’ wide with 5’ wide aisle
parking space location - 200’ max from building entrance
7-50 car lot - 2 accessible spaces
51-100 car lot - 3
101-150 car lot - 5