Cmt Flashcards

1
Q

_____: useful screening procedure for EXTRINSIC coagulation mechanism including the common pathway

  1. monitors oral anticoagulant therapy w/ _____
  2. facts with _____ to activate _____
  3. reagents
    - combination of phospholipid & protein
    - substitute for calcium
  4. RV
  5. two source of error
    - prolonged
    - shorten
  6. standardized way of reporting PT in monitoring oral anticoagulant therapy
    - Calibration Index
A

Prothrombin Time

  1. COUMADIN
  2. VII; X
    3.
    - Thromboplastin
    - 0.025M Calcium chloride
  3. 10-12s
    5.
    - heparin contamination
    - traumatic phlebotomy
  4. international normalized ratio
    - international sensitive index
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

_____: for detection of factor X deficiency
- aka
1. uses venom from
2. prolonged factor ____
3. normal ______ since it is present in venom

A

Stypven Time
- Russel Viper Venom Test
1. Vipera russelli
2. X
3. VII

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

TWO INDERECT TESTS DOR DETECTION OF FAVTOR 1

  1. _____
    - RV
    - fibrinogen level is below
  2. ____
    - RV
    - enzyme from

_____: INDERECT TEST FOR 13 DEFICIENCY
1. aka
2. Reagents (2)

A

TWO INDERECT TESTS DOR DETECTION OF FAVTOR 1

  1. Thrombin Time
    - 17-25s
    - below 75-100mg/dL
  2. Reptilase Test
    - 18-20s
    - Bothrops atrox snake

Dukert Test
1. 5M Urea Solubility Test
2. 5M urea, 1% monochloroacetic acid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Historical Tests
1. performed on serum
- deficiency in factor (6)or platelets will slow the rate of prothrombin conversion
2. adsorbed plasma/ fresh serum
- by
- uses (2)
3. required recalcification of diluted plasma
- modification of _____

A
  1. Prothrombin Consumption Tim
    - 5,8,9,10,11,12
  2. Thromboplastin Generation Time
    - Biggs & Douglas
    - Barium Sulfate/ Aluminum Hydroxide
  3. Hicks-Pitney Test
    - TGT
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Automation in Hemostasis

_____: stops assessing blood sample when there’s clot formation
1. uses _____ = semi-automated mechanical instrument
that detects fibrin strand formation using wire loop/hook

____: depends on the increase in light scattering
1. give 2 semi-automated instruments
2. give 2 automated instruments:

A

ELECTROMECHANICAL
1. Fibrinometer

PHOTO-OPTICAL
1. Electra 750 & 750A, Fibrintimer series
2. Coag-A-Mate X2 and XC;
MLA Electra 700 and 800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

_______: performed when APTT & PT are prolonged

  1. to determine whether it is caused by (3)
  2. if test DOES NOT REQUIRE (remains prolonged) when normal plasma:
  3. if repeated test is CORRECTED when mixed w/ normal plasma:
A

Substitution Test/ Mixing Studies

  1. NONSPECIFIC INHIBITOR; SPECIFIC FACTOR INHIBITOR; COAGULATION FACTOR DEFICIENCY
  2. presence of pathological circulating anticoagulant
  3. identification of deficient factor
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

FACTORS ABSENT

  1. Fresh Plasma
  2. Aged/ Stored Plasma
  3. Barium Sulfate Adsorbed Plasma
A
  1. NONE
  2. V, VIII
  3. II, VII, IX, X
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FACTORS ABSENT

  1. Fresh Serum
  2. Aged/ Stored Serum
  3. Adsorbed Serum
A
  1. I, V, VIII, XIII
  2. I, II, V, VIII, XIII
  3. I, II, V, VII, VIII, IX, X, XIII
How well did you know this?
1
Not at all
2
3
4
5
Perfectly