Chpt 3 Flashcards
It is the responsibility of the _____purchasing the fire apparatus to conduct ongoing training to ensure it’s personnel proficiency with regard to the safe and proper use of the fire apparatus and it’s equipment
Jurisdiction
From a standing start, the apparatus must be able to attain a speed of ___ within ___ on a level road
35 mph within 25 seconds
The apparatus must be able to attain a minimum top speed of ____on the level Road.
50 mph
The apparatus must be able to maintain a speed of at least 20 mph on any grade up to and including
Six percent
The maximum top speed of a fire apparatus with a gross vehicle weight rating of more than 26,000 pounds must not exceed either _____ or the manufactures maximum fire service speed rating for the tires installed on the apparatus which ever is lower
68 mph
The ______ is the bread-and-butter of the fire service. The most common type of fire apparatus, it is a part of almost every fire department.
Pumper fire apparatus
The______ is the piece of fire Apparatus that is critical for the initial extinguishment of the fire because it brings the initial water supply as well as tools to the fire scene
Pumper
Per NFPA 1901, a pumper must be equipped with a permanently mounted pump with a minimum rating of _____gallons per minute and an onboard water tank holding a minimum of___ gallons
750 gpm
300 gallons
The ______is a smaller version of the pumper that is designed to be more maneuverable than the pumper especially in off road terrain
Initial attack fire apparatus
In such circumstances, the __________ provides a scaled-down version of a pumper for responding to hard to reach areas
Initial attack fire apparatus
The initial attack fire apparatus is equipped with the fire pump as defined in NFPA 1901. the fire pump must have a minimum rated capacity of ____ gallons per minute. the apparatus water tank must have at a minimum, a certified capacity of ____.
250 gpm
200 gallons
These mobile water supply fire apparatus are commonly referred to as _____and can provide enough onboard water to extinguish most fires that are held to only one or two bedrooms of a home
Tenders
When fires are larger and more water is needed, a _________ maybe used by these types of fire apparatus to establish a sustained water supply for fire attack.
Water shuttle operation
If the mobile water supply apparatus has a fire pump, then that fire pump must meet the criteria stated in ____
NFPA 1901 chpt 16
Aerial fire apparatus are defined in NFPA 1901 and maybe classified as an ——-
Aerial ladder , elevating platform or water tower